17
Maintenanceandtroubleshooting
Type 8071
9.4.
Dismantle the device
5
4
1
2
3
grooves
Fig. 7:
Exploded view of the device
→
→
Remove the seal (mark 3 Fig. 7).
→
Examine the seal for good condition. If not, replace it by a new
one (see chap. "10. Spare parts and accessories").
→
Remove the rotors (mark 2 Fig. 7).
→
Examine the rotors for good condition. If necessary, clean or
replace them (see chap. 10).
Warning
risk of injury due to non-conforming maintenance.
• Maintenance must only be carried out by qualified and skilled
staff with the appropriate tools.
• Guarantee a set or controlled restarting of the process, after a
power supply interruption.
9.2.
maintenance of the strainer
→
After the circulation of 200 liters of fluid, examine the strainer for
particles. If necessary clean the strainer with a product compa-
tible with the materials from which it is made.
→
Regularly examine the strainer for good condition, in particular
when the flow rate decreases. If necessary clean the strainer
with a product compatible with the materials from which it is
made.
9.3.
maintenance of the device
→
Regularly examine the seal and the oval rotors for good
condition. Follow the instructions on chap. 9.4 et 9.5.
Clean the device with a cloth slightly dampened with water or a
cleaning liquid compatible with the materials the device is made of.
Your Bürkert supplier is at your disposal for any further information.
English
Summary of Contents for 8071
Page 22: ...22 Type 8071 English...
Page 23: ...23 Type 8071 English...
Page 24: ...24 Type 8071 English...
Page 44: ...22 Typ 8071 deutsch...
Page 45: ...23 Typ 8071 deutsch...
Page 46: ...24 Typ 8071 deutsch...
Page 66: ...22 Type 8071 fran ais...
Page 67: ......
Page 68: ...www burkert com...