Plus-X 300 Installation and Operation Manual Rev C 

 

two means: 1) placing the ARC Plus in maintenance mode using the ARC Plus front panel 
menus; and 2) placing the Plus-X 300 in maintenance mode using the Plus-X front panel MAINT 
button.  

When the ARC Plus is in maintenance mode, it will not issue commands or macros to any ARC 
Plus channels, including Plus-X 300 channels. It is still possible to issue test commands via the 
Plus-X 300 diagnostics page (see page 6).  

When the Plus-X 300 is in maintenance mode, the ARC Plus can issue commands and macros 
to other channels, but Plus-X 300 commands are disabled.  

Maintenance mode must be toggled from the respective front panels. For safety reasons, it 
cannot be enabled or disabled by any remote means.  

Diagnostics 

The Plus-X 300 has a diagnostics page built in to the configuration web pages. This allows 
administrators to verify raw input voltage readings against real-world measurements and to test 
relay behavior; it is not intended for routine monitoring and control of equipment.  

To access the diagnostics page, open a web browser and enter the IP address of the Plus-X 
300. After logging in, use the links at the top of the screen to navigate to the Diagnostics page. 

Getting Help 

For technical support, please email [email protected] or call our direct technical support line at 
978-486-3711. We will be glad to assist you. The technical support office is open Monday 

– 

Friday, 9AM to 5PM Eastern time. 

Warranty 

Burk Technology, Inc. warrants the Plus-X 600 to be free of defects in materials and 
workmanship for a period of 24 months from the date of purchase. Equipment will be repaired or 
replaced at the option of Burk Technology and returned freight prepaid to the customer. 
Damage due to abuse or improper operation or installation of the equipment or caused by fire or 
flood or harsh environment is not to be covered by this warranty. Damage in shipping is not the 
responsibility of Burk Technology. A return authorization must be obtained before returning any 
equipment. Materials returned under this warranty must be shipped freight prepaid and insured 
in the original shipping carton or suitable substitute to Burk Technology, Inc., 7 Beaver Brook 
Road, Littleton, MA 01460. Repairs not covered under this warranty will be made at prevailing 
shop rates established by Burk Technology. 

THE WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS 
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. BURK TECHNOLOGY, 
INC. SHALL NOT BE LIABLE TO ANY PARTY FOR ANY INCIDENTAL, SPECIAL, INDIRECT 
OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS EQUIPMENT. 

Summary of Contents for Plus-X 300

Page 1: ...Plus X 300 Installation and Operation Manual ...

Page 2: ...ight 2017 Burk Technology Inc Rev C Table of Contents Introduction 1 Compatibility 1 Installation 1 Configuration 2 Uploading New Firmware 5 Operation 5 Getting Help 6 Warranty 6 Appendix A Specifications 7 ...

Page 3: ...e current Updates are available at www burk com downloads The following are minimum software and firmware requirements Software Version ARC Plus firmware 2 0 or higher AutoLoad Plus software 2 0 or higher AutoPilot software 2 6 or higher Installation The Plus X 300 ships with the following parts which are required for installation 1 Ethernet cable 1 15V wall adapter 1 2 pin Phoenix type connector ...

Page 4: ...ower connector to the rear panel input marked POWER The power connector is pre wired to the 15V wall adapter Plug the power adapter into a standard 120V outlet The POWER LED will illuminate Finally connect the included Ethernet cable to your network switch Important The Plus X 300 must be addressable by the ARC Plus to which it will communicate Consult your IT department prior to configuration to ...

Page 5: ...for up to eight status channels as well as relay behavior for each of eight relay outputs In the Status Thresholds table enter the input values that will trigger status changes from low to high and vice versa The Lower threshold is the value below which a voltage sample must decrease in order to change the status from high to low The Upper threshold is the value above which a voltage sample must i...

Page 6: ...d the input and output channels on the Plus X 300 these channels may be added to the ARC Plus site using AutoLoad Plus To add Plus X 300 channels to the ARC Plus 1 Launch AutoLoad Plus and connect to the ARC Plus site to which the Plus X 300 is linked 2 From the Edit menu select Plus X Devices and click New 3 When the Plus X Settings window appears select Plus X 300 from the device type drop down ...

Page 7: ... password and revert the IP address to 192 168 0 100 Uploading New Firmware After logging into the Plus X 300 web interface edit the URL in your web browser to address upload where address is the IP address assigned to the Plus X 300 This will take you to the upload page Click the Choose File button to select the firmware file then click Upload to load the new firmware The Plus X 300 will reboot a...

Page 8: ...chnical support please email support burk com or call our direct technical support line at 978 486 3711 We will be glad to assist you The technical support office is open Monday Friday 9AM to 5PM Eastern time Warranty Burk Technology Inc warrants the Plus X 600 to be free of defects in materials and workmanship for a period of 24 months from the date of purchase Equipment will be repaired or repla...

Page 9: ...g Power Requirements 15VDC at 0 5A power adapter included Metering Inputs 0 to 10VDC 10mV resolution Status Inputs 0 to 28VDC or switch closure Relay Outputs 5A 240VAC form C relay outputs C NO NC each user configurable for momentary or lacthing output Hysteresis User configurable set points per input channel Mounting Keyhole slots for surface mounting Available RMA300 rack mount adapter ...

Reviews: