Burgess Furniture Configure-8 Flip-Top Table Handling, Operation & Maintenance Manual Download Page 7

Ref. “C-8 FLT O&M Manual 26-04-11”                                                                   Page 7/7 

 

3.4.4 

Inspect the castors fitted to the underside of the leg frame foot rail. There should be one 
at each end, totalling 4. Any missing or damaged castors should be replaced. 

3.4.5 

High Pressure Laminate tops with hardwood lipping:

 Light scratches and / or dents to 

the lipping may be repaired by rubbing down and re-staining. Scratches to the laminate 
itself can be improved using a colour matched filler, but it will be impossible to match the 
grain pattern. 

 

3.4.6 

Formica tops:

 Scratches to the Formica surface can be improved using a colour 

matched filler, but it will be impossible to match the grain pattern. Formica tops are edged 
with a high impact plastic which is very resistant to damage. Any damage that does occur 
will require the edging to be replaced. 

 

 

Laminate & Formica repairs: These are specialist tasks and should only be 
performed by an experienced carpenter or woodworker. If the top is more 
severely damaged it will be unlikely that a satisfactory repair can be effected 
and the top should be replaced. 

  

3.4.7 

Check that the linking clips are in place and rotate freely. These are fitted to two of the 
four plastic corner mouldings on the underside, usually front-left and rear-right when 
seated at the table. If missing or broken, the linking clips can be replaced by unscrewing 
the relevant corner moulding, replacing the linking clip, then refitting the screws to secure 
the corner moulding. 

  

3.4.8 

More severe damage should be referred to Burgess Furniture Ltd. 

 

 

ANY DEFECTIVE TABLES MUST BE REMOVED FROM SERVICE IMMEDIATELY.

 

 

3.5 Lubrication 

 

The Configure-8 Flip-Top should not need any specific lubrication. 
 

 
 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for Configure-8 Flip-Top Table

Page 1: ...Furniture Ltd Hanworth Trading Estate Feltham Middlesex TW13 6EH United Kingdom Tel 44 0 20 8894 9231 Fax 44 0 20 8894 2943 Email sales burgessfurniture com Web www burgessfurniture com Configure 8 Flip Top Tables Handling Operation Maintenance Manual ...

Page 2: ...Introduction 3 1 1 About This Manual 3 1 2 Health Safety UK 3 Section 2 Handling Storage Operation 4 2 1 Handling 4 2 2 Storage 4 2 3 Operation 5 Section 3 Maintenance Repair 6 3 1 General 6 3 2 Maintenance Schedule 6 3 3 Cleaning 6 3 4 Inspection Repair 6 3 5 Lubrication 7 ...

Page 3: ...e appropriate 1 1 4 All relevant diagrams are to be found within this manual 1 1 5 Burgess Furniture cannot be held liable for any loss damage or injury resulting from failure to follow the procedures given 1 2 Health Safety UK 1 2 1 It is the Employers duty under the Health Safety at Work Act 1974 to ensure all operational staff are aware of manual handling recommendations under the Manual Handli...

Page 4: ...ifted by a single person particularly by the centre stretcher 2 1 3 Always use the correct Manual Handling lifting technique legs bent back straight head up If the individual feels the task is too much for them alone they should seek assistance rather than risk injury and or damaging the table 2 2 Storage Unless specified Burgess products are not intended for outside use and must not be stored in ...

Page 5: ...he table where required 2 3 2 Lower the top to rest on the underframe DO NOT place hands or fingers in the hinge assembly or drop the top 2 3 3 Push down on the top to ensure both latches have engaged 2 3 4 To release the top operate the release handle by turning in either direction then lift the top to its upright position ...

Page 6: ...anodised surfaces using special abrasive blocks specifically selected for this application and available directly from Burgess These should be rubbed lengthwise on the marked area using a back and forth motion while applying light pressure DO NOT use a rotary motion as this may leave a visible abrasion on the anodised surface Abrasive scourers should not be used 3 3 2 High Pressure Laminate Real W...

Page 7: ...damage Any damage that does occur will require the edging to be replaced Laminate Formica repairs These are specialist tasks and should only be performed by an experienced carpenter or woodworker If the top is more severely damaged it will be unlikely that a satisfactory repair can be effected and the top should be replaced 3 4 7 Check that the linking clips are in place and rotate freely These ar...