background image

 

B-Smart-Lock Corona 

|

 March 2017

 

 

 01- AN/DSW English 

ǀ

 3 

Technical specifications 

Dimensions 

98 x 66 mm ; 39 mm 

Ø

  

Battery 

Lithium battery 3V, 

CR123A 

Service life: 
over 30,000 locking cycles 

Radio standard 

125 kHz 

Programming 

Multi user 

Private mode 

Material 

Casing: zamac 

Knob: plastic/ silicone 

Lock attachment  

Wood: screws 

Metal: M19 nut 

Locking direction 

L, R, LAD 

Latch 

Latch bolt in zinc 

(nickel-plated) 

Permissible temperature 

0°– 40°C 

(no formation of  
condensation) 

Private mode (fixed cabinet assignment) 

In this mode, a transponder is permanently assigned to one 
lock.  Only  this  transponder  is  then  authorised  to  close  and 
open the lock. Up to 50 transponders can be assigned at the 
same  time.  These  can  also  open  the  lock  regardless  of 
which transponder has locked it.

 

 

Automatic locking 

Automatic  locking  can  only  be  set  in  private  mode.  This 
function automatically closes the lock after a certain time.

 

Note: Automatic locking cannot be set in multi

-

user mode.

 

 

Manual locking 

The  manual  lock  secures  the  lock  only  when  a  assigned 
transponder is held in front of it. This function can be selec-
ted in private mode as an option. In multi-user mode, it is 
the only way of locking. 

 

Signal tones 

Signal tones can be turned on or off. If these are activated, 
a  beep  sounds  for  an  unauthorised  transponder,  as well  as 
opening and closing operations. 

 

LED-locking status indicator 

A  red  flash  every  second  in  the  locking  indicator  indicates 
that  the  lock  is  engaged.  When  open,  the  LED  does  not 
flash.  This  function  is  optional  and  can  be  turned  on  or  off 
as desired. 

 

Functions reset 

All functions are reset to the factory settings. 

 

Transponder reset 

This function deletes all assigned transponders. 

Note:  The  master  card  will  also  be  deleted.  The  program-
ming section describes how to assign the master card again.

 

Battery warning 

 

If  the  batteries  in  the  lock  do  not  have  sufficient  power, 
three consecutive beeps decreasing in pitch will sound when 
the transponder is held up in front of the lock. Depending on 
the frequency of lock use, the batteries must be changed in 
the next two to four weeks. When the voltage is particularly 
low, the lock can no longer be closed or can only be opened 
by  the  master  card.  If  the  batteries  are  empty,  no  action 
can be performed on the lock. 

Functional description 

Multi user mode (free cabinet selection) 

The lock can be closed by a currently unassigned transpon-
der.  Only  this  transponder  is  authorised  to  open  the  lock 
again. 
 

Multi user mode with occupied identifier 

The transponder is assigned a busy signal when it has been 
used  to  close  a  lock.  Thus,  the  transponder  cannot  close 
another lock until it has opened the first lock again. 

Mode 1 

3 seconds 

Mode 2 

6 seconds 

Mode 3 

18 seconds 

Reviews: