background image

10 

I Englsih

secuENTRY HOME 5000 CYL

A message appears stating that the 

programming file has been generated. 

Confirm the name with 

"OK"

 (Fig. 71).

Select the programming file that is 

now in the list (I) and tap on 

"Program 

(update) unit"

 (II) (Fig. 72).

Note: 

If you have generated several 

programming files for several cylinders, 

please only select the cylinder within 

the Bluetooth range of which you are 

located.

Once again you will be prompted to 

enter your administrator code (Fig. 73).

After entering the code (I), keep your 

smartphone close to the cylinder (max. 

2 m) and tap on 

"START"

 to start pro-

gramming (II).

The loading window indicates that 

programming has started and the 

current status of the programming 

(Fig. 74).

As soon as the programming has been 

completed successfully, you will receive 

a corresponding feedback. Confirm the 

name with 

"OK"

 (Fig. 75).

If the process failed, repeat the steps 

starting from step 6.

9

10

12

13

14

15

11

Fig. 73

Fig. 75

Fig. 74 

Fig. 71

Fig. 72

I

I

II

II

Opening the secuENTRY lock

Fig. 76

Proceed as follows to open the 

ENTRY Home 5000 CYL

 cylinder and 

consequently also the door:

Open the secuENTRY KeyApp and press 

the 

"GET ACCESS"

 button in the middle 

(Fig. 76).

Note: 

The secuENTRY KeyApp is 

programmed so that when more than 

one cylinder is used, it automatically 

adjusts to the cylinder that is within the 

shortest distance of the smartphone. 

Each cylinder can be opened by 

pressing the 

"Get Access"

 button.

The cylinder is now released and the 

lock can be opened (fig. 77) or locked 

(Fig. 78).

Note:

 Depending on the door stop, the 

direction of rotation may be reversed. 

1

2

!

!

!

Fig. 78

Fig. 77

Select the cylinder for which you have 

set up changes (I) (Fig. 69). 

Note: 

If you have several cylinders and 

have created changes for each, please 

only select the cylinder within the Blue-

tooth range of which you are located.

Then tap on 

"PROG.FILE"

 (II) at the top 

right (Fig. 70).

You will then be prompted to enter 

your admin code (I) and confirm with 

"OK" 

(II) (Fig. 70).

6

7

8

Fig. 69

Fig. 70

I

II

I

II

!

Summary of Contents for secuENTRY Home ENTRY 5000 CYL

Page 1: ...sured in the centre of the forend screw No drilling or laying of cables is required and it is ideally suited for both new installations and retrofitting The secuENTRY 5000 CYL can be fitted to house and interior doors The secuENTRY 5000 CYL is setup and operated using the free smartphone app secuENTRY KeyApp The transmission is wire less the cylinder uses the modern Bluetooth 5 2 standard Alternat...

Page 2: ...you have successfully registered you can start setting up the secuENTRY 5000 CYL Open the main menu Fig 4 In the following menu tap on Device Setup Fig 6 From here you can add and setup secuENTRY units to the app Use the selection menu displayed and tap on secuENTRY Profily Cylinder to setup your secuENTRY cylinder Fig 7 Tap on the menu item secuENTRY setup Fig 5 A list is displayed in which cylin...

Page 3: ...iately during setup tap on CONTINUE II Fig 13 for the corresponding request This then leads directly to the Change administrator code function which is also described in the following chapter on page 3 at point 5 Your secuENTRY cylinder is now fully setup It will now appear in the list of setup cylinders Fig 14 8 9 10 11 12 13 14 P QR I I II II Proceed as follows to delete a cylinder Open the main...

Page 4: ...been created is displayed Create a new user by tapping on the in the top right hand corner Fig 29 1 2 3 4 Fig 28 Fig 29 Fig 26 Fig 27 Create user and assign access medium There are various access media available to open your door Including opening with a user defined code the sE Key radio key and the KeyApp itself Once you have created a secuENTRY cylinder in the KeyApp you are the administrator o...

Page 5: ...n assigned the user code and the selected lock within the KeyApp Fig 31 The programming process must be started so that the cylinder also receives this information The corresponding description can be found in the chapter Programming Updating the cylinder on page 9 I I II II III Create user Radio key sE Key 1 2 3 4 Fig 32 Fig 34 Fig 33 Fig 35 Note The radio key ENTRY sE Key 7713 is available separ...

Page 6: ...39 after which a QR code is dis played on the entire screen Leave the QR code displayed on the screen and put the smartphone B aside for a moment The next steps are performed on smartphone A 1 2 3 4 5 Smartphone A The QR code displayed on smartphone B can now be scanned via the app on smartphone A Tap the QR code symbol in the Enter KeyApp line in the user menu Fig 40 You may be asked to confirm t...

Page 7: ...eceived from smartphone B on smartphone A The file can be deleted again after programming Tap on CSV in the user menu at the top right Fig 49 Select the CSV file that you received by email from smartphone B I Confirm the selection at the top right with the tick Fig 50 The data is now recorded in the KeyApp Next assign a cylinder by tapping it in the list of cylinders already registered and save yo...

Page 8: ...ired enter a new user defined code I Fig 57 Tip The entry is concealed Tap the eye symbol on the right side to visualise and check the entry Attention Do not select simple codes that are easy to guess e g 1 2 3 4 5 6 Also do not select any personal infor mation e g birthdays or other infor mation that can be easily be deduced by persons who know the user Save your settings by tapping the disk symb...

Page 9: ...ETE field II that appears on the right Fig 63 3 4 Fig 62 Fig 63 Fig 60 Fig 61 Programming updating the cylinder The cylinder must be programmed accordingly so that the registered users can now open the lock with the stored opening options Program the cylinder as follows Open the main menu Fig 64 Tap on the menu item secuENTRY setup Fig 65 Tap on Programming in the submenu Fig 66 The list of progra...

Page 10: ... from step 6 9 10 12 13 14 15 11 Fig 73 Fig 75 Fig 74 Fig 71 Fig 72 I I II II Opening the secuENTRY lock Fig 76 Proceed as follows to open the ENTRY Home 5000 CYL cylinder and consequently also the door Open the secuENTRY KeyApp and press the GET ACCESS button in the middle Fig 76 Note The secuENTRY KeyApp is programmed so that when more than one cylinder is used it automatically adjusts to the cy...

Page 11: ...data is now retrieved from the cylinder and stored in the app as a log file Fig 84 1 2 3 4 5 7 6 Fig 81 Fig 83 Fig 82 Fig 84 Fig 79 Fig 80 After retrieval a confirmation message appears which you confirm with OK Fig 85 Go back one step in the menu and tap on the item Lock history Fig 86 A list of cylinders with retrieved log files appears Select the required cylinder Fig 87 The menu of the selecte...

Page 12: ...ation of the secuENTRY 5000 CYL is explained below Prior to installation please read the installation instructions carefully Remove the existing door lock cylinder by loosening the forend screw in the door and pulling out the cylinder with the key inserted Fig 90 Remove the two hexagonal screws in the two knobs with the enclosed hexagonal spanner Fig 91 Pull off the knob on the outside completely ...

Page 13: ...age 14 of this manual Insert two new batteries Make sure that the polarity is correct according to the drawing Fig 99 Replace the front cover and screw it on tightly Fig 100 Fig 97 Fig 101 Fig 102 2 3 4 1 Fig 98 Fig 99 Fig 100 Whether for one front door several doors or a complete locking system Simply configure your individual unit with the secuENTRY modular system Your ENTRY HOME 5000 CYL cylind...

Page 14: ...to dispose of this device at any time please remember that many components of this device contain valuable materials that can be recycled Printing and typesetting errors as well as technical changes reserved Please note that electrical and electronic devices as well as batteries must not be disposed of with household waste but rather apart from it or separately Please obtain information on the col...

Page 15: ...www burg biz BURG WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany www burg biz ENTRY HOME ENTRY 5000 CYL BD Main Instruction Manual ENTRY 5000 CYL EN HBG SWI 040422 ...

Reviews: