5.9 Alarm Set
4 alarm inputs are available for „preset“, „tours“ and „pattern“.
Alarm Set: Alarm No:
Go to ALARM NO and move the joystick right in order to select one of the four
alarms.
Alarm Set: Input:
The alarm inputs are selectable as NC (Normal Close) or NO (Normal Open).
Default setting is OFF.
Alarm Set: Alarm Activation:
The alarm activated d
ifferent surveillance modes with up to 165 „preset“ numbers, 8
„group“ tours and 8 „pattern“. Move the joystick left/right to select a „preset“ number,
„group tour“ number or „pattern“ number.
Alarm Set: Save:
Once the setting and activation of the alarm input has been made, these settings can
be stored by hightlighting „SAVE“ and by moving the joystick right. After the saving is
done, the cursor goes to the next “alarm” (no. 2).
Alarm Set: Exit:
Move the joystick right to exit this page.
Default setting