USER GUIDE
TO AVOID BEING SCALDED, KEEP HANDS AWAY FROM ANY STEAM FROM THE LID
WHEN THE URN IS OPERATNG OR HAS JUST BEEN SWITCHED OFF.
TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG WHEN NOT IN USE,
BEFORE CLEANING, AND BEFORE REPLACING ANY PARTS.
Filling:
IMPORTANT:
always put water in the urn before switching on.
Remove the lid by turning anti-clockwise and fill the urn with the desired amount of water.
Do not fill above the ‘MAX’ capacity mark.
WARNING:
if the urn is overfilled there is a risk that boiling water will be ejected from
around the lid.
Underfilling may cause the thermal cut-out to operate (and may shorten the element life).
Replace the lid turning clockwise to lock.
The urn is not suitable for heating liquids other than water, or for heating water containing
solids. If the water is being heated for tea making, make the tea in another container.
Controls:
The green power indicator will be illuminated whenever power is connected to the urn.
Turn the thermostat to the desired setting, the amber heating indicator will be illuminated
whenever the element is on. This will go on and off as the the thermostat maintains the
selected temperature:
Knob setting
Approximate water temp
1
30°C
2
43°C
3
56°C
4
69°C
5
82°C
6
92°C
THIS URN IS NOT INTENDED TO CONTINUOUSLY BOIL WATER, DUE TO THE
HAZARDS OF STEAM AND WATER ESCAPING FROM UNDER THE LID.
If it is necessary to keep the water at an exact temperature, use a thermometer to check.
Stir the water before taking the temperature and when the desired temperature has been
reached, turn the control knob slowly to the left until a click from the thermostat is heard.
The thermostat will then cycle on and off to maintain the temperature.
Serving:
The tap has two open positions, one self-holding so that the tap remains open, and the
other self-closing so that the tap closes as soon as the lever is released. Lift the lever up
for the self-holding position, press the lever down for the self-closing position. Return the
lever to the horizontal position to close the tap.
After use:
Turn the control knob to 0 and disconnect from the mains supply.
Water may be left in the urn when not in use for short periods, but to maintain a supply of
fresh water, it should be emptied periodically and cleaned out.
WARNING:
only move the urn when it is disconnected and cool.
Protective cut-out:
The heating element is fitted with a thermal cut-out which protects the urn from damage if
allowed to boil dry or switched on without water. It is essential to keep the heating element
free from scale to ensure correct operation of this cut-out. Scale can cause the cut-out to
operate when water is heating up normally.
If the cut-out operates, allow the urn to cool down, drain out any water then press the red