3
•
Check that the voltage shown on the rating plate is suitable for your supply.
•
Before general use it is recommended that the urn is used on the maximum setting
twice discarding the water each time.
Fitting a plug
The mains lead of this urn will already be fitted with a BS1363 13A plug. In the event of
replacing a fuse, a 13 amp fuse approved by ASTA or BSI must be used. If the plug is not
suitable for your socket then the plug must be cut off and disposed of safely. An appropriate
plug should be fitted as follows:
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Green-and-Yellow – Earth
Blue – Neutral
Brown – Live
The wire which is coloured green-and-yellow must be connected to the terminal in the plug
which is marked with the letter E or the earth symbol or coloured green or green-and-
yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the
letter N or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked with the
letter L or coloured red or brown.
Make sure that the connections are tight and that there are no loose strands of wire and no
insulation trapped under the terminals. Tighten the clamp in the plug making sure that it grips
the outer covering of the cord. In a 13A (BS 1363) fused plug, fit a 13A fuse. Tighten the plug
cover securely.
If you are in any doubt, consult a qualified electrician.
IMPORTANT: If the supply cord is damaged, it must be replaced by the
manufacturer, service agent or similar qualified person in order to avoid a
hazard. The supply cord may become warm when the appliance is in use.
WARNING: This appliance must be earthed.
Location
•
More than 100mm from any combustible surface.
•
On a flat level surface.
•
This appliance is for indoor use only.