background image

TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER 

CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER 

FROM THE RECEPTACLE.

TROUBLE 

PROBABLE CAUSE 

ACTION

Switch is off position

Blown fuse

Tripped breaker

Dirty pressure switch

Defective pressure switch

Defective motor
Pump not primed

Leaky suction line

Foot valve plugged

Ejector nozzle clogged

Water level below foot valve

Suction lift to great

Improper voltage
Water level below foot valve

Ejector nozzle clogged

Excessive friction in pipe

Improper voltage
Leaky discharge line

Motor not up to normal speed

Improper setting of pressure switch

Ejector nozzle clogged
Pressure tank waterlogged

Leaky foot valve

Leaky suction line

Foot valve do not close properly

Pressure switch out of adjustment

Leaky discharge line (toilet etc.)
Leaky suction line

Air bubbles in water (cavitation)

Airlogged tank (galvanized)

Turn switch to on position

Replace

Reset

Clean

Replace

Replace
Prime with clean water

Check pipe and pipe connections

Clean

Clean

Check foot valve level

Water level lower than lift capacity

Check voltage
Check foot valve level

Clean

Too small or dirty pipe

Check voltage
Check all pipes for leak

Check power cable and voltage

Reset or replace

Clean
Drain tank and restart

Replace

Check pipe and pipe connections

Clean or replace

Adjust on/off setting

Check all pipes for leak
Check pipe and pipe connections

Check and consult factory

Replace air volume control

Motor does not 

run.

Motor runs but 

no water is 

delivered.

Pump does not 

deliver to full 

capacity.

Pump does not 

shut off.

Pump starts and 

stop too often.

Air spurts from 

faucets.

TO THE END CONSUMER

If you have any problems with the product, before advising the store, where 

you’ve purchased the pump, please contact us at 514 337-4415 , and ask for 

our sales department, and they will be pleased to help you with any questions 

you might have, concerning your installation.

10

Summary of Contents for 506121SW

Page 1: ...W 2015 ANDOTHERPRODUCTS 506127S 506128S 506131S etc Please read these instructions carefully Failure to comply to instructions and designed operation of this system may void the warranty 2018 BURCAM...

Page 2: ...750929 6 x 1 1 1 well seal elbow 750860 2 1 male adaptors 750865 or 750871 8 1 stainless steel clamps 750885 Teflon tape Tank installation Desired length of 1 braided hose 750919 to link up from pump...

Page 3: ...tion should be considered as well to provide the pump an environment for long life Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pip...

Page 4: ...close as possible to the basement wall Locate the suction inlet in the front of the pump body Thread an adaptor into inlet using teflon tape Do not over tighten Cut the desired length of pipe from pum...

Page 5: ...ir at the snifter valve 2 PSI below pressure switch ON setting Turn power back on to pump Your tank is now properly precharged Run the pump through a few cycles to verify that it works properly Other...

Page 6: ...voltage See above drawing on right The pressure switch setting start stop 20 40 or 30 50 has been made at the factory Adjustments may be done to give other operating pressures Adjustment or modificati...

Page 7: ...well seal and piping into well casing STEP 2 Cut poly pipe and install the check valve Check valve close to pump STEP 3 Insert well seal elbow through the seal and attact to pipe STEP 7 You may insta...

Page 8: ...djust air pressure To home s plumbing distribution line Pressure switch 1 4 connection if not included with the pump Pressure gauge 1 4 connection Drain valve 1 2 connection 1 MNPT or 3 4 FNPT connect...

Page 9: ...ump bracket 20 506383 Motor flange cap screw 21 506074GP Fan cover Ref Part Description 22 506073W Motor fan 23 506072GP Motor end bell 24 506385 Wave spring washer 25 350335 Motor bearing fan side 26...

Page 10: ...ir bubbles in water cavitation Airlogged tank galvanized Turn switch to on position Replace Reset Clean Replace Replace Prime with clean water Check pipe and pipe connections Clean Clean Check foot va...

Reviews: