Table 2
Work duration (sek.)
Concentration of silver
water, mg/l
Work duration (min.)
Concentration of silver
water, mg/l
2 sek.
5 sek.
10 sek.
15 sek.
30 sek.
60 sek.
0,010
0,027
0,056
0,082
1,170
0,339
5 min.
10 min.
15 min.
20 min.
30 min.
40 min.
60 min.
90 min.
108 min.
1,671
3,315
5,022
6,613
9,950
13,27
20,00
30,00
35,00
8. PRODUCTION OF SILVERED WATER (MODIFICATION KL)
8.1.
Holding the lower container (1) on its handles (2) remove the enclosure (9) of the device.
8.2.
Put the holder with the round silver electrode (17) on the contact (18) located on the enclosure (9).
8.3.
Take out the removable vessel (3).
8.4.
Pour water into the lower container (1) up to the lower mark (6).
8.5.
Put the enclosure (9) on the lower container (1).
8.6.
Connect the plug of the string type cord (13) to the electricity supply socket. Turn on the switch (20).
Green indicator (14) on the enclosure must light and letter
S
must appear in the timer indicator (16).
From the table 2 choose duration of working time of the device.
Working time of the device until 1 minute is set in seconds, from 1 to 40 minutes in minutes.
8.7.
Pushing time indicator button (16) indicated by arrow Ç to set the time of electrolysis. To reduce the set
time push the button (16) indicated by the arrow É.
8.8.
Push the button START. Red indicator (11) lights up indicated by letter
J
. The device starts working.
After the set time passes the device switches off automatically. To make a premature cancellation of the
work of the device push the button STOP.
8.9.
Pull the plug of the cord (13) from a socket, take off the enclosure (9), pour out the silvered water into
the non-transparent, tight jar that has to be stored in a dark place.
8.10.
Carefully clean the silver electrode (17) and the light flat electrode (19) with a soft cloth dipped in
vinegar. Dark varnishes occurring on the silver electrode do not influence the quality of silvered water.
8.11.
Dry the lower container (1) and the enclosure (9). Assemble the device and store it in dry place.
8.12.
When producing silvered water for a longer time period dark spots occur on the bottom of the lower
container (1). It is a residual effect of silver sediments. These spots do not influence the quality of
silvered and activated water and further exploitation of the device.
It is PROHIBITED to wash with water the enclosure (9) containing the electric part!
9. SAFETY REQUIREMENTS
9.1.
The device can be connected to the power supply when the lower container (1) and the removable
vessel (3) are filled with water and the enclosure (9) is put on.
9.2.
The device should be protected from children and shouldnÅt be left without attendance.
9.3.
IT IS PROHIBITED:
9.3.1. To remove the enclosure (9) from the lower container (1) when the device is connected to the power
supply.
9.3.2. To keep the operating device near open fire, sparking devices.
9.3.3. To switch on the device for longer 40 minutes when producing ionized water.
9.3.4. To reassemble, wash the enclosure (9) of the device with water.
9.3.5. To assemble the device that has not dried up after the use.