LOWLANDER MK4 MANURE SPREADER – INSTRUCTION & SPARES MANUAL
Page
18
1.11 LOAD CELL DIAGNOSTICS
There are several things that can be checked to diagnose load cell issues.
1.11.1 INSTRUMENT DIAGNOSTICS
1.11.1.1
In “Diagnostics – Loadcell Interfaces” is there a voltage and weight reading?
YES & Wrong – It could be the angle sensor or loadcells –
1.11.1.2
NO – It could be an issue with the loadcells or the CAN communication -
1.11.1.2
1.11.1.2
Is there an angle reading in “Diagnostics – Angle Sensor”?
YES & Correct – It is likely to be a problem with the load cells –
1.11.3
YES & Wrong – Re-calibrate the angle sensor on level ground
NO – It is likely there is a problem with the general CAN communication –
1.11.2
1.11.2 CAN DIAGNOSTICS
1.11.2.1
Check the power in the weighing module
Mk5/Atlas Loadcell Interface – Check if there is a constant red power light on the front.
YES – Power supply is correct –
1.11.2.2
NO – No Power –
1.11.2.3
Mk4 Loadcell Interface – Open the Loadcell Interface and check if there is a constant green power
light.