![Bunn SINGLE Operating & Service Manual Download Page 40](http://html.mh-extra.com/html/bunn/single/single_operating-and-service-manual_2831053040.webp)
Page 40
If voltage is not present as described, refer to the
Wiring
Diagrams
and check brewer wiring harness.
5. Disconnect wires from the warmer element.
6. Check the continuity across the two terminals on
the warmer element.
If continuity is present as described, reconnect the
white or red and white/red wires or the white or red
and white/violet wires on the warmer element.
If continuity is not present as described, replace the
warmer element.
Removal and Replacement:
1. Remove the three #4-40 slotted head screws se-
curing the warmer assembly to the brewer base.
2. Lift the warmer assembly from the brewer base.
3. Disconnect the two wires from the warmer element
terminals.
4. Remove the two #8-32 nuts securing the warmer
element to the warmer plate.
5. Securely install new warmer element.
6. Reconnect the two wires to warmer element ter-
minals.
7. Securely install warmer assembly in brewer
base.
8. Refer to Fig. 33 when reconnecting wires.
SERVICE (cont.)
WARMER ELEMENT
Location:
The warmer element is located in the base of the
brewer under the warmer plate.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Use the white wire or red wire to the terminal block
and the white/violet wire to the warmer element.
3. With a voltmeter, on 120V, 120/208V or 120/240V
models, check the voltage across the white wire
and the white/violet wire with the "ON/OFF" switch
in the "ON" position. With a voltmeter, on 200V or
240V models check the voltage across the red wire
and the white/violet wire with the "ON/OFF" switch
in the "ON" position. The indication must be:
a.)120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models.
b.)200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
1
2
3
4
5
.5
MIN
UT
ES
BU
NN-O-
MA
TIC
P/N
26
20-
12
0 V
AC
P2229
P841
27038 030901
WHI/VIO to Timer TL1 (Electro/mechanical)
WHI/RED to Timer TL1 (Electronic)
WHI to Terminal Block (120V,
120/208V or 120/240V Brewers)
RED to Terminal Block (200V or
240V Brewers
FIG. 33 WARMER ELEMENT TERMINALS
FIG. 32 WARMER ELEMENT