ELECTRICAL REQUIREMENTS

 

The 120V rated Nitron Gas Module has an attached cord set and requires a 2-wire, grounded, individual branch circuit 

rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector is NEMA 5-15R. 

Refer to the data plate for exact electrical requirements.

CAUTION: 

To reduce the risk of Electric Shock or Injury, use and store indoors only. Adapter plugs

 

or extension cords

 

may 

not

 be used to facilitate electrical hook-up to the equipment power cord.

GROUNDING INSTRUCTIONS

 

This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock 

by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an 

appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance 

with all local codes and ordinances.

WARNING: 

Improper installation of the grounding plug is able to result in a risk of electric shock. When repair or 

replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal. The 

wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

Contact a qualified electrician or serviceman when the grounding instructions are not completely understood, or 

when in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it does not fit

the outlet, have the proper outlet installed by a qualified electrician.

 

   

 

SITE REQUIREMENTS

 

The Nitron Gas Module dimensions are 8.3"W x 13.8"D x 4.7"H. The NGM should be placed in a upright position on 

a solid surface nearest or directly underneath the Nitron Cold Draft Dispenser. Environment must be below 90 Degrees F, 

50% or lower humidity, such as in a cafe, convenience store, or restaurant and not near other appliances that may emit 

gasses, oils, or other fluids. 

Do Not 

allow vents on the sides of the NGM to get blocked.

CAUTION: 

To reduce the risk of Electric Shock or Injury, use and store indoors only. Adapter plugs

 

or extension cords

 

may 

not

 be used to facilitate electrical hook-up to the equipment power cord.

APPLICATION: 

The NGM is not to be used with a Keg style dispense systems. The output pressure of the NGM will be 

around 100-112psig.

120 Volt 

Plug

Summary of Contents for NITRON2 NGM

Page 1: ...D 07 19 2019 Bunn O Matic Corporation INSTALLATION OPERATING GUIDE Bunn O Matic Corporation Post Office Box 3227 Springfield Illinois 62708 3227 Phone 217 529 6601 Fax 217 529 6644 www bunn com NGM Ni...

Page 2: ...or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while...

Page 3: ...e Maintenance 8 Troubleshooting 9 Wiring Schematic 11 INTRODUCTION The Nitron Gas Module NGM is specifically designed to work with Nitron Cold Draft dispensers It sup plies an unlimited amount of gas...

Page 4: ...o not direct air stream at body To reduce Risk of Injury WARNING FAILURE TO COMPLY RISKS EQUIPMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE USING THIS PRODUCT 00986 0002M 10...

Page 5: ...uthorized Service personnel only CE REQUIREMENTS This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where...

Page 6: ...ot connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Contact a qualified elec...

Page 7: ...ing with Step 2 Step 2 Place the Nitron Gas Module NGM near or under the Nitron dispenser Adjust to extend the feet of the Nitron dispenser approximately 1 0 inch to accommodate NGM placement undernea...

Page 8: ...d product for the consumer Assures uptime Eliminate premature replacing of equipment Reduce problematic repairs return service trips NGM Annual PM For optimal performance all four internal filters sho...

Page 9: ...sealed and electrical connections tight and isolated WARNING Exercise extreme caution when servicing electrical equipment Unplug the dispenser when servicing except when electrical tests are specifie...

Page 10: ...icted Nitron Gas Module filter Inspectentirepressurizedlinefrom Nitron Gas Module to the nitron2 Cold Draft dispenser Ensure proper Nitron Gas Module placementaccordingtoSiterequire ments Replace miss...

Page 11: ...ION SCHEMATIC WIRING DIAGRAM NITRON GAS MODULE 120 VOLTS AC 2 WIRE SINGLE PHASE 60hZ GRN WHI BLK 120V MODELS N A B A B L1 SOLENOID VALVE SOL BLU BLU AIR PUMP PRESSURE SWITCH MOTOR START CAPACITOR WHI...

Reviews: