Excess noise from the Nitron Gas
Module.
Nitron Gas Module won’t start.
Unusual air pump longer run times.
1. Hose connection leaking.
2. Improper placement on a unstable
surface.
3. Nitron Gas Module missing or
defective rubber foot.
1. Check main power supply for
power and/or low voltage.
2. Defective start capacitor.
3. Thermal overload tripped in Nitron
Gas Module.
4. Plugged pressure line.
1. A restricted Nitron Gas Module
filter.
Inspect entire pressurized line from
Nitron Gas Module to the nitron
2
Cold Draft dispenser.
Ensure proper Nitron Gas Module
placement according to Site require-
ments.
Replace missing or defective rub-
ber foot.
Ensure main power is on and within
/-10%.
Replace start capacitor.
Rating: 250VAC, 50/60Hz
7.0µF (-5/+10%)
a) Wait for thermal overload to cool
down and reset.
b) Relocate or correct environ-
ment conditions around Nitron Gas
Module.
Inspect and repair.
Perform PM and record annual PM
event on Filter Change sticker.
PROBLEM
PROBABLE CAUSE
REMEDY
TROUBLESHOOTING
CONTINUED