SET-UP INSTRUCTIONS
1. After connecting to a filtered water source (see PLUMBING REQUIREMENTS), turn on the water supply to
the dispenser.
2. Connect the Nitrogen source to the dispenser, but DO NOT turn on the Nitrogen supply or open the tank’s
valve until specified.
3. Connect the LED lighting from the door cover to the door. Install the door using the 5 mounting screws
provided. (See DOOR COVER INSTALLATION)
4. Confirm that the dispense switch (located in upper right corner of door when open) is in the OFF position.
5. Connect the switches from the handle set to the wire harness on the door (note right and left connections).
Install the handle set using the two screws on the bottom side of the handles. Snap the plug in the hole on
the door under the handles.
CAUTION: Improper electrical installation will damage electronic components.
• An electrician must provide electrical service as specified.
• Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
Plug the dispenser into a 120V power source. Set the dispense switch to the ON position.
The water bath will fill automatically when dispenser is provided power and water, program mode OFF and dis-
pense switch ON.
NOTE: There will be a flashing red LED light at the top center of the door’s artwork. This light indicates there is
currently no Nitrogen coming into the dispenser (via a pressure detect switch). This switch will turn On when
pressure reaches <100 psi and turn Off when pressure reaches >115 psi.
Do not open the nitrogen tank valve until instructed to do so.
6. Remove the drip tray and splash panel.
7. Once the water bath is full, turn the water bath pump/compressor switch to ON.
• It will take a full 4 hours to build the ice bank required for optimal dispenser performance. During this
time, some further trickling from the water bath into the drip tray is expected due to expansion caused
by the ice bank formation.
8. Install dispense nozzles and drip tray. The nozzle with the Nitro Stout Insert goes in the LEFT dispense sta-
tion. The nitro stout insert’s function is to provide back pressure while dispensing Nitro Coffee and aides in
creating the “cascading” or surging effect in the dispensed drink.
54261.0001 090817