PROGRAMMING THE DISPENSER
Remove the lower splash guard assembly to access the digital programming module with LCD display.
Press the Down Arrow key to inter the programming menu.
Use the Up and Down Arrow keys to scroll through the menu screens.
Select Exit to leave the programming function and return to normal operations.
NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
TANK TEMP XXX
CABINET TEMP XX
L DISPENSE RATIO
(-) 35:1 (+)
SET LF TUBE SIZE
1/8 EXIT 3/16
R DISPENSE RATIO
(-) 35:1 (+)
SET RT TUBE SIZE
1/8 EXIT 3/16
FLAVOR GUARD ?
NO EXIT YES
MENU SCREEN
ACTION
DESCRIPTION
LF TASTE OK ?
NO EXIT YES
FIND LF TARGET
PULL DISPENSE
RT TASTE OK ?
NO EXIT YES
FIND RT TARGET
PULL DISPENSE
If NO - go to LF DISP VOLUME menu.
Use the Down Arrow Key
to enter Programming
Functions
Use the (+) or (-) buttons to
adjust the Mix Ratio
Select tube size.
Use the (+) or (-) buttons to
adjust the Mix Ratio
Select tube size.
Select (YES) to activate.
Select (NO) to deactivate.
Select (YES) or (NO)
Place a 16 Oz. (500 mL)
cup under the Left dispense
tip, then activate the Left
dispenser
Select (YES) or (NO)
Place a 16 Oz. (500 mL) cup
under the Right dispense
tip, then activate the Right
dispenser
Normal Display for LCR models.
Enter the desired Mix Ratio for the concentrate
used in the Left dispenser. [20:1 - 100:1]
Enter Pump Tube Size to be used in the Left
metering pump, (see Tube Selection Chart)
Enter the desired Mix Ratio for the concentrate
used in the Right dispenser. [20:1 - 100:1]
Enter Pump Tube Size to be used in the Right
metering pump, (see Tube Selection Chart)
Select Yes, if you are ready to calibrate the Flavor
Guard sensor. Select NO, if you do not wish to
use this feature, (see Flavor Guard)
Select YES, if you have dispensed several cups
and are satisfied with the Left dispenser flavor.
Select NO, if you have not run taste test.
Calibrates the Left FlavorGard™ sensor to the
current MixProfile. The dispenser will shut OFF
automatically when finished.
Select YES, if you have dispensed several cups
and are satisfied with the Right dispenser flavor.
Select NO, if you have not run taste test.
Calibrates the Right FlavorGard™ sensor to the
current MixProfile. The dispenser will shut OFF
automatically when finished.
36026 042104