18
SERVICE (cont.)
AUGER DRIVE COMPONENTS (cont.)
Auger Drive Motor (Refer to Figs. 2 & 3)
1. Remove all hopper assemblies (20) and set aside
for reassembly.
2. Remove the four #8-32 screws securing the hop-
per support plate (19), and hopper locator bracket
(21) remove plate and bracket and set aside for
reassembly.
3. Remove the four #8-32 locking screws, located
inside the dispenser housing on the front of the
auger motor mounting panel (14), securing auger
motor mounting bracket (15) and auger motor
(16) to the rear of the auger motor mounting panel
(14).
4. Disconnect the wires from the auger motor (16) to
be removed.
5. Remove auger motor mounting bracket (15), au-
ger motor (16) and dust seal (17) as an assembly.
6. Remove dust seal (17) from auger motor (16).
7. Remove the four #8-32 screws securing the auger
motor to the auger motor mounting bracket.
8. Remove auger motor and discard.
9. Using four #8-32 screws, install new auger motor
(16) on mounting bracket (15).
10. Install dust seal (17) on auger motor shaft.
11. Using four #8-32 locking screws install auger
motor, dust seal and mounting bracket to the rear
of the auger motor mounting panel (14)
12. Reconnect the wires to the terminals on the auger
motor.
13. Install hopper support plate (19), hopper locator
bracket (21) and all hopper assemblies (20).
14. Refer to Fig. 4 when reconnecting wires.
LEFT
CENTER
RIGHT
RED to WHI/RED to
Control Board J1-7
RED to WHI/ORN to
Control Board J1-5
BLK to GRN from
Control Board J1-8
BLK to GRN from
Control Board J1-8
BLK to GRN from
Control Board J1-8
P1639
FIG. 4 AUGER MOTOR TERMINALS
RED to WHI/
BLU to
Control
Board J1-6
29215 101598