ELECTRICAL REQUIREMENTS

CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.

Model 35 requires 3-wire, 

grounded service rated 120/208 

or 120/240 volts ac, 20 amp, 

single phase, 60 Hz.  Proceed as 

follows:

Model 20 requires 2-wire, 

grounded service rated 120 volts 

ac, 20 amp, single phase, 60 Hz.  

Proceed as follows:

Electrical Hook-Up

CAUTION – Improper electrical installation will damage electronic components.

1.  An electrician must provide electrical service as specified.

2.  Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.  Place the heater switch at the rear of the brewer in the “OFF” lower position.

4.  Remove the front panel beneath the sprayhead.

5.  Feed the cord through the strain relief and connect it to the terminal block.

6.  Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.  Re-

place the front panel.

7.  If plumbing is to be hooked-up later be sure the brewer is disconnected from the power source.  If plumbing 

has been hooked-up, the brewer is ready for Initial Set-Up.

“A" & "B” models require 

2-wire, grounded service rated 200 

volts ac or 240 volts ac, 20 amp, 

single phase, 50 Hz. Proceed as 

follows:

10478.1 051412

GREEN

GREEN

200 or 230V. A.C.

BLK

RED

L1

L2

GREEN

GREEN

BLK

RED

120V. A.C.

120V. A.C.

208 or 240V. A.C.

WHI

L1

L2

N

GREEN

GREEN

120V. A.C.

BLK

WHI

L1

N

CE Requirements:

• This appliance must be installed in locations where it can be overseen by trained personnel.

• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.

• Appliance shall not be tilted more than 10° for safe operation.

• An electrician must provide electrical service as specified in conformance with all local and national codes.

• This appliance must not be cleaned by water jet.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of 

this appliance by a person responsible for its safety.

• Children should be supervised to ensure they do not play with the appliance.

• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel 

with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.

• Machine must not be immersed for cleaning.

PLUMBING REQUIREMENTS

  These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi 

(138 620 kPa) from a 

1

2

" or larger supply line.  A shut-off valve should be installed in the line before the brewer.  

Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa).  The 

water inlet fitting is 

1

4

" flare.

NOTE - Bunn-O-Matic recommends 

1

4

" copper tubing for installations of less than 25 feet and 

3

8

" for more than 25 

Summary of Contents for CRT5

Page 1: ...st revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the...

Page 2: ...ions to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Page 3: ...PMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE BUYING OR USING THIS PRODUCT THIS APPLIANCE IS HEATED WHENEVER CONNECTED TO A POWER SOURCE 00831 0000F 3 98 1998 BUNN O MATIC...

Page 4: ...N GREEN 120V A C BLK WHI L1 N CE Requirements This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where th...

Page 5: ...l water is dispensed 10478 1 051412 feet from the 1 2 water supply line A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop Bunn O Matic does not...

Page 6: ...nces 9 If not disconnect the brewer from the power source remove the front panel and adjust the brew timer as required See Adjusting Brew Volumes Replace the front panel connect the brewer to the powe...

Page 7: ...ll not stop the flow of water into the funnel until the tank syphons down to its proper level Placing the switch in the ON upper position supplies power to the brew station warmer and enables the brew...

Reviews: