USER NOTICES

Carefully read and follow all notices in this manual and on the equipment.  All labels on the equipment should 

be kept in good condition.  Replace any unreadable or damaged labels.

 

 

                 

# 12364.0000

WARNING 

!

Fill water tank before turning - on -  

thermostat or connecting appliance 

to power source. 

Use only on a properly protected 

circuit capable of the rated load. 

Electrically ground the chassis. 

Follow national/local electrical codes. 

Do not use near combustibles. 

FAILURE TO COMPLY RISKS EQUIPMENT 

DAMAGE, FIRE, OR SHOCK HAZARD 

READ THE ENTIRE OPERATING MANUAL 

BEFORE BUYING OR USING THIS PRODUCT 

THIS APPLIANCE IS HEATED WHENEVER 

CONNECTED TO A POWER SOURCE 

00831.0000F  3/98   ©1998  BUNN-O-MATIC CORPORATION 

As directed in the International Plumbing Code of the 

International Code Council and the Food Code 

Manual of the Food and Drug Administration (FDA), 

this equipment must be installed with adequate 

backflow prevention to comply with federal, state 

and local codes. For models installed outside the 

U.S.A., you must comply with the applicable Plumb-

ing /Sanitation Code for your area.

PN: 00658.0000G  02/08  © 1985 BUNN-O-MATIC CORPORATION

# 00656.0001

# 00658.0000

# 00831.0000

10478.1 052412

#00824.0002

Summary of Contents for CRT5

Page 1: ...st revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the...

Page 2: ...ions to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Page 3: ...PMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE BUYING OR USING THIS PRODUCT THIS APPLIANCE IS HEATED WHENEVER CONNECTED TO A POWER SOURCE 00831 0000F 3 98 1998 BUNN O MATIC...

Page 4: ...N GREEN 120V A C BLK WHI L1 N CE Requirements This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where th...

Page 5: ...l water is dispensed 10478 1 051412 feet from the 1 2 water supply line A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop Bunn O Matic does not...

Page 6: ...nces 9 If not disconnect the brewer from the power source remove the front panel and adjust the brew timer as required See Adjusting Brew Volumes Replace the front panel connect the brewer to the powe...

Page 7: ...ll not stop the flow of water into the funnel until the tank syphons down to its proper level Placing the switch in the ON upper position supplies power to the brew station warmer and enables the brew...