TROUBLESHOOTING (cont.)
PROBLEM
Dispenser is making unusual noises.
(Some noises are a normal
occurance with this type of device.
You need to become familiar with
those that are normal, to determine
when they have become unusual.)
(cont.)
Product is leaking into the inside of
the drum.
PROBABLE CAUSE
3. Fan Motor
4. Auger Motor(s)
1. Worn Shaft
2. Worn Seals
REMEDY
Remove the air filter at the rear of the
dispenser and listen for fan motor
noise. Replace the motor if exces-
sively noisy.
Place the Auger switches in the "ON"
position and the ICE/OFF/NO-ICE
switches in the “OFF” position. Lis-
ten for auger motor noise. Replace
the motor if excessively noisy.
Replace Shaft. Refer to
Service -
Auger Shaft Assembly. See page 24.
Replace Cooling Drum Seal. Refer to
Service - Auger Shaft Assembly. See
page 24.