Bunn AUTOPOD BREWER Programming Manual Download Page 7

Page 7

EXTERNAL RELAY Main control board outputs 12vdc to activate external relay. 

The N.O. contact then closes to provide line voltage to the heater in HOT WATER 

TANK.

EXTERNAL RELAY
 ON    NEXT    OFF

INDEX MOTOR DUMP runs the pod holder back to the pod ejection position. 

LOAD moves it out to the door open position. "B  " indicates the assembly is 

in home postion.

INDEX    B       MOTOR

DUMP    NEXT     LOAD

TEST OUTPUTS allows testing of load components by manually turning them 

ON/OFF.  

---PLACE A 10 OUNCE CUP UNDER DISPENSE AREA---

WARNING: HOT WATER WILL DISPENSE DURING SOME TEST MODES!

   TEST OUTPUTS  ?

NO                      YES

PROGRAM FUNCTIONS

DRIP TIME (A/B) (OFF/1-50 seconds)

Time between brew cycle and pod ejection.

BREWS TO EMPTY (OFF/15-25)

Set number of used pods in bin to turn on "EMPTY BIN" message.

ENABLE ENERGY SAVER

Choose to have the tank heaters turn off, or reduce the tank temp to (140° F) 

or (60° C) once the "SET IDLE TIME" has expired. .5-50.0 hrs.
AIR PUMP POWER (1 Weakest - 4 Strongest ) 

Adjust air pressure for end of brew cycle purge. Due to pod variations, reduce 

as needed if splattering occurs.
BREW COUNTS

Retains the total number of brew cycles completed, not reset-able.

BREW COUNTS

Retains the total number of brew cycles completed, reset-able.

CALIBRATE FLOW

This function allows you to enter the actual flow rate of the sprayhead by dispens-

ing for one minute. The volume is then entered in ounces per minute. (Oz/M)
Place a 10 ounce or larger measuring cup under sprayhead and press one of 

the brew switches. 

After dispense finishes, read number of ounces and enter that amount into brewer 

using the +/- switches, then press "DONE" to set the volume into memory.

AIR PUMP POWER  4

(-)         DONE        (+)

Enabl EnergySavr

NO          DONE       YES

BREWS TO EMPTY

(-)           25          (+)

DRIP  T I M E  A/B:  15

(-)         DONE        (+)

   BREW COUNT  ##

RESET     NEXT

   BREW COUNT  ##

NO                        YES

CALIBRATE FLOW  ?

NO                        YES

PRESS

BREW TO START

ENTER OZ     10.0

(-)         DONE        (+)

CONTINUED

SERVICE TOOLS allows testing of load components and switches.

It should only be used by trained technicians.

   SERVICE TOOLS  ?
NO                      YES

411701 061308

Summary of Contents for AUTOPOD BREWER

Page 1: ...PROGRAMMING MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 41170 0000B 05 12 2010 Bunn O Matic Corporation ...

Page 2: ...ions to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no cha...

Page 3: ...Page 3 411701 061308 CONTENTS LOCKOUT SWITCH 4 PROGRAMMING SWITCHES 5 PROGRAMMING 6 ...

Page 4: ...ne of the programming switches are pressed within one minute during programming the display will return to the MAIN SCREEN Always remember to place an empty cup under the sprayhead when operating the brewer during the set up of PULSE BREW CALIBRATE FLOW and testing the brew valve in SERVICE TOOLS TEST OUTPUTS Mounted on main control board This switch can be set to prevent access to the programming...

Page 5: ...and hold the hidden switch Release when the display reads BREW LOCKOUT TheYESorNOshouldbeflashing SelectYEStoprevent brewingifthewatertemperatureisbelowthesetREADY temperature Select NO to permit brewing at any water temperature Whenfinished pressandreleaseDONE Thiswillstepto the next function screen To return to the MAIN SCREEN at any time press and hold the hidden switch BREW LOCKOUT NO DONE YES...

Page 6: ...ber as a password SET LANGUAGE Choose between English or Spanish UNITS METRIC DONE ENG SET LANGUAGE NO YES ENTER ASSET NO YES SET TEMP 200 DONE SET READY 195 DONE UNITS Choose between English Oz F or metric Ml C SET TEMP Adjust tank temperature 185 to 205 F 85 to 96 C SET READY Sets the minimum temperature allowable to start a brew cycle if BrewLockout is enabled Range 2 to 20 F or 2 to 10 C below...

Page 7: ...he SET IDLE TIME has expired 5 50 0 hrs AIR PUMP POWER 1 Weakest 4 Strongest Adjust air pressure for end of brew cycle purge Due to pod variations reduce as needed if splattering occurs BREW COUNTS Retains the total number of brew cycles completed not reset able BREW COUNTS Retains the total number of brew cycles completed reset able CALIBRATE FLOW Thisfunctionallowsyoutoentertheactualflowrateofth...

Page 8: ...ON NEXT OFF WATER PUMP N A WATER PUMP ON NEXT OFF HOT WATER AIR PUMP Activates the air pump motor for the hot water tank HotWaterAir PUMP ON NEXT OFF TANK HEATER Activates the triac relay on the main control board for the brew tank heater TANK HEATER ON NEXT OFF Press the hidden program switch to go back to previous screen Pressing any other membrane switch will give corresponding readout for that...

Page 9: ...Page 9 411701 061308 ...

Reviews: