Manual-SMT 3000 ECO LIGHT Plus-en
page 8 / 18
Safety and protective measures
Warning
To maintain the required operational safety, please note the following:
•
Touch the placement and dosing pipettes with caution. The small diameter of the pipettes can
easily injure a person's skin.
•
This device is operated electrically. When operating electrical devices, certain parts within these
devices are inevitably under dangerous voltage.
•
Failure to observe the operating instructions can result in death, serious physical injury or consid
-
erable damage to property!
•
Never open a device housing.
•
Do not misuse the device. Only use this according to its sense of use in accordance with the oper
-
ating instructions.
•
Only a service technician commissioned by BUNGARD GmbH & Co.KG is allowed to repair the
devices.
•
If necessary, also observe the special safety regulations of your country.
Operation and maintenance
There are no parts on the manipulator SMT 3000 ECO that require regular maintenance.
However, to ensure trouble-free operation for years, you should note the following points:
•
Keep the workplace clean. Contamination of the device or the vacuum pump can lead to prema
-
ture wear. For example: rusting of the metal parts, wear of the guides or failure of the vacuum
pump.
•
Test the placement arm guidance at regular intervals. If this wobbles, you can adjust the play on
the guide slide of the manipulator bridge.
•
Test the vacuum created. If, for example, you can no longer accommodate larger components
properly, please check whether the vacuum pump generates sufficient vacuum. If this is the case,
please check the pipette and the vacuum filter.
Note
If you have any other problems with your manipulator or you cannot solve one of the
problems mentioned, our service is at your disposal at any time.
Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany
Tel.: +49 (0) 2292/9 28 28 - 0, Fax: +49 (0) 2292/9 28 28 - 29, E-mail: [email protected]