Principle o

f Oper

ation / Battery P

ack

EVAHL Series - Principle of Operation 

The EVAHL Series Powered Air-Purifying Respirator (PAPR) System is configured in
six parts:
1.  The blower and belt assembly: 

EVAHL1 Blower Unit 
EVABELT1 or EVABELT2 Comfort Belt, Decon Belt 
PA1AFI Air Flow Indicator

2.  The battery pack (Part No. EVAHLBAT1). One fully charged pack will power the blower 

for approximately 4 to 10 hours depending upon factors such as speed, cartridge 
selected and cartridge loading.

3.  The breathing tube, which is available in three different types and three lengths: 
    PAHBT Powered Air Hood Breathing Tube Assembly (standard length - 26") 
    PAHBTXS Powered Air Hood Breathing Tube Assembly (short length - 22") 
    PAHBTXL Powered Air Hood Breathing Tube Assembly (long length - 32")  
    PA1BT Hood breathing tube assembly with clamp (standard length - 26")  
    PA1BTXS Hood breathing tube assembly with clamp (short length - 22")  
    PA1BTXL Hood breathing tube assembly with clamp (long length - 32")  
    PA20LFBT Loose fitting facepiece breathing tube assembly (standard length - 32") 
    PA20LFBTXS Loose fitting facepiece breathing tube assembly (short length - 26") 
    PA20LFBTXL Loose fitting facepiece breathing tube assembly (long length - 38")
4. The High Efficiency Particulate Arrestance (HEPA) filter or chemical filter cartridge.
5.  The hood with headband suspension (except for the RT Series) and/or hard hat, or 

loose fitting facepiece. The following hood models may be used with the EVAHL Series 
blower unit: 
 RT1, RT1T Hood with long inner and outer bib (NIOSH approved for use without a 
headband suspension) 
 RT2, RT2T Hood with long inner and outer bib (NIOSH approved for use without a 
headband suspension)

 

RT3, RT3T Hood with long inner and outer bib (NIOSH approved for use without a  

 

headband suspension) 
RT4, RT4T Hood with long inner and outer bib (NIOSH approved for use without a  

 

headband suspension) 
20TJN, 20TJNT Hood 
20TICN, 20TICNT Hood with inner bib 
20TICH, 20TICHT Hood for use with Bullard hard hat 
20TICSN, 20TICSNT Hood with taped and sealed seams 
20SICN, 20SICNT Hood with taped and sealed seams 
20SICVN, 20SICVNT Hood with taped and sealed seams and PVC lens 
20SICH, 20SICHT Hood with taped and sealed seams for use with Bullard hard hat 
20SICVH, 20SICVHT Hood with taped and sealed seams and PVC lens for use with  

 

Bullard hard hat 
20LFM Loose fitting facepiece, medium size 
20LFL Loose fitting facepiece, large size 
20LFXL Loose fitting facepiece, extra large size 
20LF2S Loose fitting facepiece (narrow profile), small size 
20LF2M Loose fitting facepiece (narrow profile), medium size 
20LF2L Loose fitting facepiece (narrow profile), large size

6.  The Battery Charger: 

EVAHLSMC Quick charger, single port 
EVAHLGC Gang charger, six port

The blower unit draws in ambient air through the cartridges. The purified air is blown 
into the wearer’s hood through the breathing tube. A flow indicator is provided to check 
that there is an adequate volume of air available to the wearer prior to use. The system is 
designed to operate at a minimum air flow of approximately 7 cubic feet of air per minute 
(198 liters per minute) in the hood under normal use on the standard speed setting, and 
8.5 cubic feet of air per minute (240 liters per minute) in the hood under normal use 
on the high speed setting. A feedback loop from the Mass Flow Sensor to the impellor 
continually monitors and adjusts the air flow to keep it constant at the design set point.
The units are designed for use at temperatures from 23ºF to 129ºF (-5ºC to 55ºC).
A high temperature alarm will sound at 122ºF (50ºC).

The battery pack mounts in a compartment on the back of the blower. A fully charged 
battery pack will power the blower for approximately 4 to 10 hours depending upon 
factors such as speed selected, cartridge selected, and filter/cartridge loading.
The EVAHL Series Blower is equipped with two alarms: A continuous alarm will sound when 
the air flow falls below approximately 185 lpm and an intermittent chirp alarm will activate 
to indicate that the battery has approximately 15 minutes of remaining capacity.

Battery Pack  

One fully charged battery pack will power the blower for approximately 4 to 10 hours 
depending upon factors such as speed selected, cartridge selected and filer/cartridge 
loading.

WARNING: 

EXPLOSION HAZARD

•  Only use Bullard battery part number: EVAHLBAT1. Substitution of any other 

battery pack may impair suitability for Division 2.

•  Do no charge battery packs in hazardous locations. 
• Only charge using Bullard Desktop battery pack chargers.
•  Do not insert or remove the battery pack unless the area is known to be free 

of ignitable concentrations.

 

 NOTE

 

 The battery has built-in short circuit protection. In the event of a short circuit, an 
internal polyfuse will trip. The fuse will reset itself within 5-10 seconds allowing the 
battery to resume normal operation.

To charge the battery pack, do the following: 
• Use a flat head tool to release the battery from the blower. (See Figure 1.)
•  Place battery into the charging port of the battery charger. (See Figure 2.)
• Connect the battery charger to a 110-volt AC electrical outlet.
• Charge the battery pack for approximately 4 hours. While the battery is charging, the 
light on the charger will remain red. The charger light will illuminate green when charging 
is complete. 

Figure 1

Figure 2

Summary of Contents for EVAHL Series

Page 1: ...t use these respirators for respiratory protection during abrasive blasting or clean up 4 Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards 5 Leave area immediately if Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant U...

Page 2: ...edium size 20LF2L Loose fitting facepiece narrow profile large size 6 The Battery Charger EVAHLSMC Quick charger single port EVAHLGC Gang charger six port The blower unit draws in ambient air through the cartridges The purified air is blown into the wearer s hood through the breathing tube A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior t...

Page 3: ...terioration physical damage and improper assembly 2 Filter Cartridges Inspect the filter cartridge for any physical damage Check the label to ensure the filter cartridge has not exceeded its use by date Inspect the gasket on the filter for any phsyical damage NOTE Each filter comes with a permanent gasket Ensure that the correct filter cartridge is appropriate for the contaminant Consult the NIOSH...

Page 4: ...particulate filters are 99 97 effective against all particulate aerosols The following abbreviations are approved by NIOSH to indicate the particulates gases or vapors which are removed by the gas vapor cartridges HE High Efficiency Particulate OV Organic Vapor AM Ammonia CD Chlorine Dioxide CL Chlorine FM Formaldehyde HC Hydrogen Chloride HF Hydrogen fluoride MA Methylamine SD Sulfur Dioxide Moun...

Page 5: ...ead during use first verify proper air pressure then select a different hood for your application or use the optional chin strap Adjusting and Installing Hard Hat in Respirator Hood 20SICH 20TICH 1 Assemble and adjust the standard Bullard hard hat suspensions RS4PC or RS6PC or the optional ratchet suspensions RS4RC or RS6RC by following the directions on instruction sheet attached to headband on h...

Page 6: ...hing 6 Ensure that the neck cuff is down below the chin and that the air outlets of the cuff see Figure 27 are not restricted If the neck cuff is not below the chin then pull down before continuing See Figure 27 RT Series Hood Use Installing Breathing Tube Assembly in RT Series Respirator Hoods For hoods without a threaded port at the rear Breathing Tubes PA1BT PA1BTXS and PA1BTXL will attach to t...

Page 7: ...ttach the other end of breathing tube to blower unit if not already attached by screwing adapters together Remove any protective film covering the lens of the headpiece Put on the belt and blower assembly and make any final adjustments to the belt as necessary keeping the breathing tube and hood behind the head Turn the blower on by depressing and holding the on off switch Figure 33 for approximat...

Page 8: ...will automatically cease operation Doffing the Respirator Prepare to doff the blower battery and hood in a safe hazard free area and do the following in conjunction with your employer s standard operating procedures Remove the hood Turn the blower off by holding down the ON OFF switch for 5 seconds This is confirmed by a long beep and a shut down of the motor Remove the waist belt Disconnect the h...

Page 9: ...SSEMBLIES ALTERNATE SUSPENSION HARD HAT ASSEMBLIES ALTERNATE BREATHING TUBES ALTERNATE BLOWER UNIT ASSEMBLIES FILTER ASSEMBLY ALTERNATE CARTRIDGE ASSEMBLIES ALTERNATE BATTERY CONFIGURATIONS ALTERNATE BELT ASSEMBLIES ALTERNATE CHARGER ASSEMBLIES ACCESSORIES CAUTIONS AND LIMITATIONS2 20LFXL 20LFL 20LFM 20LFXLHE 20LFLHE 20LFMHE 20LF2L 20LF2M 20LF2S 20LF2LHE 20LF2MHE 20LF2SHE 20TJN 20TJNT 20TICN 20TIC...

Page 10: ...ullard will accept any returned goods Please read carefully Follow the steps outlined below to return goods to Bullard for repair or replacement under warranty or for paid repairs 1 Contact Bullard Sales Support by telephone or in writing at Bullard 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Phone 859 234 6616 In your correspondence or conversation with Sales Support de...

Page 11: ...cepieceTychem 2000Traditional Large HEPA 20LFMHE 20LF LF FacepieceTychem 2000Traditional Medium HEPA 20LFXLHE 20LF LF FacepieceTychem 2000Traditional XL HEPA Double bib hood for use without a headband suspension RT1 RT1T Tychem 2000 QC Inflatable neck collar RT2 RT2T Tychem 4000 SL Inflatable neck collar RT3 RT3T Tychem 2000 QC Sport neck collar RT4 RT4T Tychem 4000 SL Sport neck collar Accessory ...

Page 12: ...59 234 6616 Fax 1 859 246 0243 Americas Operations 1898 Safety Way Cynthiana KY 41031 USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Bullard GmbH Dieselstrasse 8a 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Bullard Asia Pacific Pte Ltd 51 Changi Business Park Central 2 03 04The Signature Singapore 486066 Tel 65 6745 0556 Fax 65 6797 0299 ...

Reviews: