Bullard COHP User Instructions Download Page 4

Americas:

E.D. Bullard Company

1898 Safety Way  
Cynthiana, KY  41031-9303
Toll free: 877-BULLARD (285-5273)
Tel: 859-234-6616 
Fax: 859-234-8987

www.bullard.com

Europe:

Bullard gmbH

Lilienthalstrasse 12
53424 Remagen • Germany
Tel: +49-2642 999980 
Fax : +49-2642 9999829

www.bullardextrem.com

Asia-Pacific:

Bullard Asia Pacific Pte. Ltd.

LHK Building
701, Sims Drive, #04-03 
Singapore 387383
Tel: +65-6745-0556 
Fax: +65-6745-5176

www.bullard.com

©2009 Bullard. All rights reserved.

6081257991B (0909)

ISO 9001 

certified

Return Authorization

The following steps must be completed before Bullard will accept any returned goods. Please read carefully.
Follow the steps outlined below to return goods to Bullard for repair or replacement under warranty or for paid repairs:
1.  Contact Bullard Customer Service by telephone or in writing at: 

 

Bullard

 

1898 Safety Way 

 

Cynthiana, KY 41031-9303 

 

Toll-Free: 877-BULLARD (285-5273) 

 

Phone: 859-234-6611 

In your correspondence or conversation with Customer Service, describe the problem as completely as possible. For your convenience, the representative will try to help you correct the problem over the phone.

2.  Verify with your representative that the product should be returned to Bullard. Customer Service will provide you with written permission and a return authorization number.
3.  Before returning the product, decontaminate and clean it to remove any hazardous materials which may have settled on the product during use. Laws and/or regulations prohibit the shipment of hazardous or 

contaminated materials. Products suspected to be contaminated will be professionally discarded at the customer’s expense.

4.  Ship returned products, including those under warranty, with all transportation charges pre-paid. Bullard cannot accept returned goods on a freight collect basis.
5.  Returned products will be inspected upon return to the Bullard facility. Bullard Customer Service will telephone you with a quote for required repair work which is not covered by warranty. If the cost of repairs 

exceeds stated quote by more than 20%, your representative will call you for authorization to complete repairs.

CO Monitor Troubleshooting guide

Monitor will not calibrate at 10 ppm.

1.  Prior to performing a calibration, allow the temperature of the monitor to stabilize to the environment in which it will be used for several 

minutes.

2.   The Clean Air Box should be under pressure with air flowing to the box with no air going through the outlet couplers 
   (i.e. under static pressure). 
3. Perform a zero point adjustment using impurity-free air. 
4. If the instrument zeroes, perform a calibration using 10 ppm CO. 
5. Verify that the calibration gas is 10 ppm and the gas cylinder is not empty. (Gauges are available.) 
6. If the instrument will not calibrate, remove the air supply and repeat both the zero point adjustment and the 10 ppm CO calibration. 
7.  If the instrument will not calibrate, replace the sensor and repeat both the zero point adjustment and the 10 ppm CO calibration.

Monitor will not successfully complete a zero point adjustment.

• Wait 5 minutes and repeat steps 1-4 above. 

Monitor displays a (-0) reading or rc.

• Wait 5 minutes and repeat steps 1-6 above.

Monitor zeroes during the zero point adjustment and the reading 

elevates after returning to the RUN mode.

A. Allow unit to stabilize in the run mode for 5 minutes. 
B. Repeat steps 1-6 above. 
C. If the unit will not calibrate, the supply air may be contaminated. 
D. Check the supply air for CO level.

Monitor will not turn ON.

• Verify that the ON/OFF button under the front cover of the monitor has been pressed to activate the monitor 
• Check AC power supply 

1. Confirm the ON/OFF switch on the control box is in the ON position
2. Confirm AC power cord is connected to working outlet (Portable)
3. Confirm unit is wired correctly (Panel mount)

• Using Battery back up

1. Confirm the AA batteries are good – replace if needed

• Using 9V battery installed in monitor

1. Verify that the battery is good – replace if needed

•  If the power supply is good and the monitor will not power up, return it to the factory for repair or replacement.

Monitor does not display flashing green light after calibration or a 

partial display appears on the monitor screen.

• With the monitor ON and the unit on battery power only, remove and reinstall the 9 volt battery.
• Repeat steps 1-6 above.

Monitor does not turn OFF.

• Monitor must be in the RUN or TEST mode.

Monitor displays an (F1) reading.

• The rotary cam switch is not locked in the CAL, TEST or RUN position.
• Turn the switch knob slightly until it is in the correct position.

NOTE

1. AC appears on the display if attempting to go to CAL mode.
2. CO and an alternating number appears on the display if the unit 
    is in the TEST mode.
3. A number (PPM content of CO in the compressed air) appears 
    on the display if attempting to go to the RUN mode.

Monitor displays (8.88, 2F or 9E) with flashing lights.

• This can occur when the ON / OFF button is pushed while the monitor is in the fault mode with F1 showing on the display.
• Continue to push the ON / OFF button until F1 is shown on the display.
• Turn the switch knob slightly to lock the monitor into the CAL, TEST or RUN   mode.

Monitor shuts down after 60 second countdown.

• Check power supply.
• Verify that the battery is good.
• If the power supply is good and the monitor will not power up, return it to the factory for repair or replacement.

Monitor displays “lb”.

 This indicates a low battery condition and the 9V battery in the CO monitor should be replaced.

Yellow caution LED flashes.

• This is normal for TEST mode and no action is necessary. 
• If the unit is not in TEST mode, then it may indicate a low battery condition.  Replace the 9V battery in the CO monitor.

Distributed By:

Summary of Contents for COHP

Page 1: ...ibrationgasintothecenteroftheknob Thereadingonthemonitorshouldbe10 1if applyingCOgas Thereadingonthemonitorshouldbezeroor1ifapplyingthezerogas Inthetest mode thesuppliedairwillnotbemonitoredandthereisnoneedtoturnthesuppliedairoffwhen enteringthismode Unitmustbezeroedafterabumptestisperformed CAListhecalibrationandzerocalibrationmode WhenthemonitorisswitchedtoCAL thesupplied airwillnotbeflowingtoth...

Page 2: ...mbienttemperatureschange allowtheunittostabilizefor15 20minutespriortoZeroPointadjustmentandcalibration Zero Point Adjustment ZerocalibrationshouldbeperformedbeforecalibratingthemonitorwithCOgas Bullard recommendsusingimpurityfreetestgastore zeroandwheneverthezero pointhasdrifted Zero Adjustment Procedure RemovethefrontcoveroftheCOMonitor PushtheONbutton Theunitwillbeepandbegina60secondcountdown R...

Page 3: ...emovingthefrontofthehousingfromtheCOM5orCOM10 monitor Togainaccesstothesensor removethefourscrewsonthefrontoftheCOmonitoronly After removingthefourscrews gentlyprythefrontofthehousingofffromthebottomofthehousing warning Removing the front of the housing by prying at the top will result in damage to the housing This damage is not covered under warranty Gentlypullouttheoldsensor Removetheshortingcli...

Page 4: ...on 7 If the instrument will not calibrate replace the sensor and repeat both the zero point adjustment and the 10 ppm CO calibration Monitor will not successfully complete a zero point adjustment Wait 5 minutes and repeat steps 1 4 above Monitor displays a 0 reading or rc Wait 5 minutes and repeat steps 1 6 above Monitor zeroes during the zero point adjustment and the reading elevates after return...