AIR FILTER REPLACEMENT SCHEDULE

Regular inspection and replacement of the Air Filters will prevent extensive and costly pump
repairs. Dirty or clogged filters can be responsible for failure of the pump to build up outlet pres-
sure and eventual overheating.

– Replace the Carbofine Outlet Filter Cartridge (Cat. No. S17101) at least once every 200 run-

ning hours or sooner if necessary.

The Outlet Filter Cartridge is multi-layered with 40-micron size particles of activated carbon, a
sorbent bed with an exposed carbon surface of more than 15,000 square feet.

Vapor Removal Efficiency: 90-95%

D.O.P. Efficiency: (0.3 to 0.6 Micron Particles) 99.97%

Solid Particle Filtering: 0.2 Micron and Larger.

Liquid Particle Filtering: 0.75 Micron and Larger

– Replace the medium efficiency Inlet Filter (Cat. No. 23611) at least once every 500 running

hours or sooner if necessary.

The Inlet Filter keeps moisture as well as particulates larger than 25 micron out of the air
supply and helps protect the pump’s carbon vanes.

We recommend the following chart be used to monitor and maintain a routine Air Filter replace-
ment schedule.

CARBOFINE OUTLET FILTER CARTRIDGE

MEDIUM EFFICIENCY INLET FILTER

(Cat. No. S17101)

(Cat. No. 23611)

Cumulative 

Cumulative

Pump

Last Filter

Employee

Pump

Last Filter

Employee

Operating

Replacement

Responsible

Operating

Replacement 

Responsible

Hours

Date

(Initial)

Hours

Date

(Initial)

200

500

400

1,000

600

1,500

800

2,000

1,000

2,500

1,200

3,000

1,400

3,500

1,600

4,000

1,800

4,500

2,000

5,000

16

Summary of Contents for ADP20

Page 1: ...READ ALL INSTRUCTIONS BEFORE USING THIS PUMP ADP20 Free Air Pump Instruction Manual The Human Side of Safety Since 1898...

Page 2: ...tor Works 7 How Motor Drives Pump 7 How Pump Supplies Air 7 Installation 7 8 OPERATING THE FREE AIR PUMP 9 10 MAINTAINING THE FREE AIR PUMP Maintaining the Air Motor 11 Maintaining the Pump 11 12 Ensu...

Page 3: ...95 psig may result in an inadequate supply of air to the worker See below for pump performance On the charts below find the relevant Output Air Pressure psig corresponding to the respirator s approve...

Page 4: ...16 5 Three Two One 22 14 5 Three Two One 25 11 4 Two One One Assumes that no air is being dumped form the Pressure Relief Valve and that pump s drive air pressure is maintained at 95 psig It should be...

Page 5: ...pressure gauge on the pump is maintained above the minimum pressure set ting required by the respirator manufacturer To be assured your respirator can be used with this pump refer to the section in th...

Page 6: ...questions concerning the use of this pump or your respirator or you are not sure the Inlet Air Filter is located at a source of clean breathable air ask your supervisor All instructions for the use a...

Page 7: ...30 psig S16222 6 Outlet Filter Cartridge S17101 7 Heat Exchanger 8 Quick Disconnect Couplers Female 1 2 industrial interchange S16191 9 Air Motor 10 Throttle Valve 11 Plug 12 Lubricator 13 Oil Meterin...

Page 8: ...G 7 1 Grade D or higher as specified by Federal Law 30 CFR Part 11 Subpart J 11 121 b The requirements of Grade D breathable air include Oxygen 19 5 23 5 Hydrocarbons condensed in mg m3 of gas 5 mg m3...

Page 9: ...metered 3 Lubricated air passes through THROTTLE VALVE 10 and drives AIR MOTOR 9 4 Air is exhausted through motor exhaust muffler 18 to atmosphere How Motor Drives Pump MOTOR drives pump through a fle...

Page 10: ...d psig on OUTLET AIR PRES SURE GAUGE 5 and adjust OIL METER ING SCREW 13 until lubricator is produc ing approximately 1 DRIP PER MINUTE in the SIGHT DOME 14 NOTE This drip rate should be monitored occ...

Page 11: ...respirator s minimum approved pres sure will be found in the respirator s Instruction Manual and or on labels attached to the respirator If you have any questions as to whether or not your respirator...

Page 12: ...ure range by adjusting the Throttle Valve 10 9 With the air flowing put on the respirator by following the directions in the respirator manufacturer s Instruction Manual YOU ARE NOW READY TO ENTER THE...

Page 13: ...oons of solvent into the opening d Replace the Plug reconnect the airline back to the Drive Air Inlet Turn the pres sure back on e Run the pump at a very low speed 10 20 RPM for approximately 1 minute...

Page 14: ...oil less pump ONLY THE AIRMOTOR CAN BE LUBRI CATED BEARINGS are grease packed and sealed They require no further lubrication Ensuring Pump Performance To make sure your pump will perform properly 1 Al...

Page 15: ...necessary Check drive air inlet pressure Check for leaks in air hose Verify proper pressure range for your respirator Verify that respirator and hose are connect ed when gauge reading is taken Check...

Page 16: ...ilter 244852 Outlet filter jar aluminum jar only 263552 Outlet Filter Assembly O Ring 10 per pkg 21052 Conversion kit V15 Coupler 1 4 Industrial Interchange with male 3 8 NPT V23 Quick disconnect coup...

Page 17: ...responsible for damages for loss of use or other indirect incidental consequential or special costs expenses or damages incurred by the purchaser notwithstand ing that Bullard has been advised of the...

Page 18: ...rticle Filtering 0 2 Micron and Larger Liquid Particle Filtering 0 75 Micron and Larger Replace the medium efficiency Inlet Filter Cat No 23611 at least once every 500 running hours or sooner if neces...

Page 19: ...duct to Bullard This will include information which must be included on the shipping carton for proper receiving and handling by Bullard DO NOT return product without first following this procedure 3...

Page 20: ...ght 1995 by Bullard All rights reserved including the right of reproduction in whole or in part in any form 6094000023 1198 1898 Safety Way Cynthiana KY41031 9303 Toll free 800 827 0423 Phone 606 234...

Reviews: