AIR FILTER REPLACEMENT SCHEDULE
Regular inspection and replacement of the Air Filters will prevent extensive and costly pump
repairs. Dirty or clogged filters can be responsible for failure of the pump to build up outlet pres-
sure and eventual overheating.
– Replace the Carbofine Outlet Filter Cartridge (Cat. No. S17101) at least once every 200 run-
ning hours or sooner if necessary.
The Outlet Filter Cartridge is multi-layered with 40-micron size particles of activated carbon, a
sorbent bed with an exposed carbon surface of more than 15,000 square feet.
●
Vapor Removal Efficiency: 90-95%
●
D.O.P. Efficiency: (0.3 to 0.6 Micron Particles) 99.97%
●
Solid Particle Filtering: 0.2 Micron and Larger.
●
Liquid Particle Filtering: 0.75 Micron and Larger
– Replace the medium efficiency Inlet Filter (Cat. No. 23611) at least once every 500 running
hours or sooner if necessary.
The Inlet Filter keeps moisture as well as particulates larger than 25 micron out of the air
supply and helps protect the pump’s carbon vanes.
We recommend the following chart be used to monitor and maintain a routine Air Filter replace-
ment schedule.
CARBOFINE OUTLET FILTER CARTRIDGE
MEDIUM EFFICIENCY INLET FILTER
(Cat. No. S17101)
(Cat. No. 23611)
Cumulative
Cumulative
Pump
Last Filter
Employee
Pump
Last Filter
Employee
Operating
Replacement
Responsible
Operating
Replacement
Responsible
Hours
Date
(Initial)
Hours
Date
(Initial)
200
500
400
1,000
600
1,500
800
2,000
1,000
2,500
1,200
3,000
1,400
3,500
1,600
4,000
1,800
4,500
2,000
5,000
16