88VX Series Airline Respirator
User Manual
Br
eathing Air Pr
essur
e T
able
9
Breathing Air Pressure Table
This table defines the air pressure ranges necessary to provide 88VX Series respirators with a volume of air that falls within the required range of
6-15 cfm or 170-425 lpm according to U.S. Government regulations (42 CFR, Subpart J, 84.150, Table 8).
1
2
3
4
5
6
Flow Control Valve/
Air Supply
Air Supply
Maximum Number
Required Pressure
Air Source
Climate Control Device
Hose
Hose Length (feet)
of Hose Sections
Range (psig air)
Stationary
F30, F30B, F30S, F31, F32,
V10
25
1
14-15
or Portable
F33, F34, F37, F38
50
2
15-18
Air Compressor
100
3
19-24
150 4
23-29
200 5
25-34
250-300
5
31-39
V5
25
1
12-18
50
2
19-23
F40, F40B, F40S, F41, F42,
V10
25
1
22-25
F43, F44, F47, F48
50
2
24-27
100
3
27-32
150
4
30-37
200
5
33-40
250-300
5
38-45
V5
25
1
22-26
50
2
25-30
AC100030, AC100030B,
V10
25-50
2
55-65
AC100030S, AC100031,
75-150
3
60-70
AC100032, AC100033,
175-300
5
65-75
AC100034, AC100037,
ACC100038
V5
25
1
55-65
50
1
56-69
DC5040, DC5040B,
V10
50
2
48-52
DC5040S, DC5041,
100
3
59-63
DC5042, DC5043,
150
3
68-72
DC5044, DC5047,
200
3
80-84
DC5048
250
3
85-92
300
5
90-98
V5
25
1
53-57
50
2
67-71
HC240030, HC240030B,
V10
25
1
61-63
HC240030S, HC240031,
50
2
63-65
HC240032, HC240033,
100
3
68-70
HC240034, HC240037,
150
4
73-75
HC240038
200
4
77-79
250
5
80-82
300
5
84-86
V5
25
1
65-66
50
1
68-69
Bullard
F35, F35B, F35S
V20
50
1
4-6
Free-Air
®
100
2
6-8
Pumps
200
2
10-15
300
3
13-18
Frigitron 2000
V20
50
1
16-22
Frigitron 2000B
100
2
18-25
Frigitron 2000S
200
2
22-30
300
3
25-34