List of Materials

4

www.build.com

(3) Wire Nuts

(3) M6 x 1-1/2” 

(2) M6 x 1” 

(4) 3/16” x 1/4”

(2) M3.5 x 8

(1) 5 x 12

PARTS NOT SUPPLIED

- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Duct cover extension accessory
- Recirculating kit accessory

HARDWARE PACKAGE CONTENTS

(1) Light Bulb Removal
     Suction Cup 

PARTS SUPPLIED

MODELS: 

MH00330G & MH00336G

1 - Hood with internal blower
1 - Duct cover wall bracket
1 - Duct cover assembly (top and bottom)
1 - 6” round backdraft damper (pre-installed)
2 - 50W GU-10 halogen light bulbs (pre-installed)
1 - Stainless steel mesh filter  
1 - Canopy, glass 
1 - Hardware package

Summary of Contents for MH00330G

Page 1: ...Installation Use and Care Guide READ AND SAVE THESE INSTRUCTIONS MODEL MH00330G MH00336G ...

Page 2: ...www build com ...

Page 3: ...ing Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Mechanical Controls 11 MAINTENANCE Hood and Filter Cleaning 12 Lights 13 TROUBLESHOOTING 14 WIRING DIAGRAMS 15 LIST OF PARTS AND ACCESSORIES 16 Table of Contents ...

Page 4: ...ONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d U...

Page 5: ...on is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a quali ed electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a ...

Page 6: ...des Duct cover extension accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS 1 Light Bulb Removal Suction Cup PARTS SUPPLIED MODELS MH00330G MH00336G 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bottom 1 6 round backdraft damper pre installed 2 50W GU 10 halogen light bulbs pre installed 1 Stainless steel mesh filter 1 Canopy glass 1 Hardware pack...

Page 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Page 8: ...ld result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 16 fo...

Page 9: ...ing option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating side wall cap w gravity damper blower housing blower housing blower housing blower housing ...

Page 10: ... www build com Installation Hood Specifi cation 17 1 4 8 15 16 15 7 8 6 7 8 19 3 4 10 5 8 23 15 16 10 3 8 30 or 35 3 16 Min Ducted 23 Min Recirc 27 Maximum 42 FRONT SIDE TOP BACK 2 5 16 3 15 16 3 15 16 6 ...

Page 11: ... x 1 screws FIG A 3 9 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 10 Power up hood to verify all functions and check for leaks around duct tape 11 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct cover bracket using 2 M3 5 x 8 screws 12 Reinstall stainless steel mesh fi...

Page 12: ...ed from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal lters charcoal lter brackets and air diverter plate Hood Model Part No Filters in Pkg MH00330G MH00336G RHRK003S 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket FIG B Run 6 ducting from top of hood and secure to air diverter...

Page 13: ... Blower Speed Selection Blower Off The blower will be powered off by pressing Blower Speed Selection Select one of three speed levels by pressing Lights On Off Power lights on and off by pressing 3 Features Controls Mechanical Controls ...

Page 14: ...tton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Stainless Steel Mesh Filters The mesh filter s installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing detergent and ...

Page 15: ...turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part numbers please turn to...

Page 16: ...a m a D 5 h c t i w s e h t e g n a h C 6 e v i t c e f e d s i h c t i w s e h T 6 The unit is vibrating 1 The blower is not secure in place 1 Tighten the blower in place r e w o l b e h t e c a l p e R 2 l e e h w r e w o l b d e g a m a D 2 3 The hood is not secured in place 3 Check the installation of the hood The blower is working but the lights are not 1 Light socket plug is disconnected 1 C...

Page 17: ...15 Wiring Diagrams MH00330G MH00336G ...

Page 18: ...GU 10 50W each Z0B 0020 Optional Accessories Recirculating Kit RHRK003S Replacement Charcoal Filter RHCF001 Duct Cover Extension up to 12 ceiling RHEX003S To order parts email us at vsupport ventingservices com or call us at 1 888 750 1698 List of Parts Accessories ...

Page 19: ... you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SE...