background image

finishing the activities, before servicing, or when 
the appliance is not used. 

After use, always store the appliance safely, 

outside the reach of children. 
 

ELECTRICAL SAFETY

 

 

Always check that the power 

supply corresponds to the 

voltage on the rating plate. 

 

DESCRIPTION BPS130 

Your welder has been designed for welding 
metal. 
 
1 On/off switch 
2 Adjustment knob welding current 
3 Temperature indicator 
4 Handle 
5 Welding cable 
6 Earth cable 
 

DESCRIPTION BPS180R 

Your welder has been designed for welding 
metal. 
 
1 Magnetic Shunt 
2 Power supply Cable 
3 On and off switch & supply voltage selection 
switch 
4 Graduated welding amperage scale. 
5 Electrode Cable 
6 Earth cable 
 

Fitting the mask  

Fit the handle (7) to the mask (8) as shown. 

Firmly press the handle. 

 

 

Always wear the mask to 
protect your eyes. 

 

Fitting an electrode  

Press the handle of the welding cable, keep it 

depressed and place the electrode into the 
clamp . 

Release the handle. 

 

Instructions for use 

Fit an electrode into the clamp of the welding 

cable. 

Connect the clamp of the earth cable directly 

to the workpiece or to the workbench. 

Hold the mask before your face. Look 

through the window in the mask during use. 
 

 

Always wear the mask to 
protect your eyes. 

 

 

Always wear suitable gloves to 
protect your hands. 

 

Finishing the welding area 

Clean the welding area using the brush . 

Remove welding slags using the slag hammer . 

 

 

Wear safety glasses to protect 
your eyes. 

 

Switching on and off  

To switch the appliance on, set the on/off 

switch (1) to ‘I’ (BPS130) / “ON” (BPS180R) 

To switch the appliance off, set the on/off 

switch (1) to ‘0’(BPS130) / “OFF” (BPS180R

 

 

The appliance has been fitted 
with a thermal protection. In 
case of overload the 
transformer is switched off. 
After the transformer has 
cooled down the appliance 
automatically switches on 
again. 

 

Setting the welding current 

The welding current depends on the diameter of 
the electrode. 

Use the adjustment knob to set the welding 

current. 

Consult the following table for the correct 

setting. 
 

WELDING CURRENT 

With electrode diameter (Ø) 
 
1,6 mm 

A 30-50 

2,0 mm 

A 50-75 

2,5 mm 

A 70-95 

3,2 mm 

A 80-125 

4,0 mm 

A 115-160 

 

CLEANING AND MAINTENANCE 

The appliance does not require any special 
maintenance. 

Regularly clean the ventilation slots. 

 
 

Summary of Contents for 5411074119584

Page 1: ...BPS130 BPS180R FR POSTE DE SOUDURE NL LASAPPARAAT GB WELDER 2010...

Page 2: ......

Page 3: ...alimentation d nergie 3 Bouton marche arr t 4 balance gradu e d amp rage de soudure 5 c ble d lectrode 6 c ble de la terre NL 1 Instelknop lasstroom 2 Kabel van energie 3 Aan uit schakelaar 4 weegsch...

Page 4: ...eil si le c ble d alimentation est endommag ou us Avant d utiliser la rallonge lectrique examinez la pour d tecter une possible usure ou un endommagement En cas d endommagement d branchez imm diatemen...

Page 5: ...e lectrode dans la cosse du c ble de soudure Reliez la cosse du c ble de masse directement la pi ce ouvrer ou l tabli Maintenez le masque devant vos yeux Regardez travers la fen tre du masque pendant...

Page 6: ...rode 1 6 mm 39 2 0 mm 21 39 2 5 mm 8 32 3 2 mm 15 4 0 mm 7 Nombre d lectrodes pour une soudure entre un red marrage apr s la derni re intervention du thermostat et la suivante Avec un diam tre d lectr...

Page 7: ...k het apparaat niet als het netsnoer is beschadigd of versleten Controleer voor gebruik het verlengsnoer op mogelijke slijtage en beschadiging Verwijder in geval van beschadiging direct de netstekker...

Page 8: ...in de klem Laat de hendel los Aanwijzingen voor gebruik Breng een elektrode aan in de klem van de laskabel Breng de klem van de aardkabel direct aan op het werkstuk of de werkbank Houd het masker voor...

Page 9: ...n op kamertemperatuur voor interventie thermostaat Bij elektrodediameter 1 6 mm 39 2 0 mm 21 39 2 5 mm 8 32 3 2 mm 15 4 0 mm 7 Aantal elektroden bij lassen tussen herstart na laatste interventie en vo...

Page 10: ...ged or worn Before use check the extension cord for possible wear and damage In case of damage immediately remove the mains cable from the wall socket Do not touch the cable before the mains cable has...

Page 11: ...nect the clamp of the earth cable directly to the workpiece or to the workbench Hold the mask before your face Look through the window in the mask during use Always wear the mask to protect your eyes...

Page 12: ...ter 1 6 mm 39 2 0 mm 21 39 2 5 mm 8 32 3 2 mm 15 4 0 mm 7 Number of electrodes when welding between restart after last thermostat intervention and next thermostat Intervention With electrode diameter...

Page 13: ...are parts under www eco repa com D Sie k nnen Updates von Handb chern zu finden Explosionszeichnungen und Informationen zu Ersatzteilen unter www eco repa com IT possibile trovare gli aggiornamenti de...

Page 14: ...de Goz e 6110 Montigny le Tilleul Belgique T l 0032 71 29 70 70 Fax 0032 71 29 70 86 Made in China S A V 32 71 29 70 88 32 71 29 70 99 Service Parts separated 32 71 29 70 83 32 71 29 70 86 2010 Made i...

Reviews: