6
EN
Cleaning, Care & Maintenance
• Always turn off and disconnect the appliance from the power supply before
cleaning.
• Always allow the appliance and oil to cool before cleaning.
• Check the temperature with a suitable probe thermometer; 40ºC is the MAXIMUM temperature at
which oil should be removed.
• For best performance, BUFFALO recommend that the appliance is cleaned after each day of operation.
• Pull the air filter out of its slot on the bottom of the appliance. Clean with a vacuum cleaner.
Note: Failure to clean the appliance regularly may result in premature activation
of the thermal cut-out switch.
Empty and clean the oil tank
• When the oil has cooled sufficiently, lift the tap lever and rotate anti-clockwise to the ON position. Let
the drained oil flow into a container.
Tap: ON position
Tap: OFF position
• If the oil is to be reused then filtering it before refilling will extend the oil’s cooking life.
• Use a suitable detergent to clean the oil tank.
• Let it dry well, ensuring no moisture enters the inside of the appliance.
Note:
• To carry out a comprehensive cleaning, the plate
as shown needs to be removed. Otherwise oil
collates in behind.
• To remove the plate, the screw as shown needs
to be removed first.
Before handling and unscrewing, ensure to
allow the appliance to cool.
Screw
Plate
Cleaning all removable parts
• Use warm, soapy water and a soft brush to clean the lid, basket and batter plate.
• Dry thoroughly.
CP793_CT012_ML_A5_v6_20220707.indb 6
CP793_CT012_ML_A5_v6_20220707.indb 6
2022/7/6 17:07