: 0845 146 2887 (United Kingdom)
Cleaning, Care & Maintenance
•
Always turn off and disconnect the appliance from the power supply before cleaning.
•
Use soapy water and a damp cloth to clean the exterior of the appliance.
•
Dry thoroughly after cleaning.
•
The spout filter slides out for ease of cleaning.
•
Periodically clean the inside of the appliance using a suitable descaling solution.
Troubleshooting
Technical Specifications
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being
required they must be readily accessible.
Compliance
The WEEE logo on this product or its documentation indicates that the product must not be
disposed of as household waste. To help prevent possible harm to human health and/or the
environment, the product must be disposed of in an approved and environmentally safe recycling
process. For further information on how to dispose of this product correctly, contact the product
supplier, or the local authority responsible for waste disposal in your area.
BUFFALO parts have undergone strict product testing in order to comply with regulatory standards
and specifications set by international, independent, and federal authorities.
BUFFALO products have been approved to carry the following symbol:
|All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of BUFFALO.
Every effort is made to ensure all details are correct at the time of going to press, however, BUFFALO reserve the
right to change specifications without notice.
Fault
Probable Cause
Action
The unit is not
working
The unit is not switched on
Check the unit is plugged in correctly and switched
on
Plug and lead are damaged
Call BUFFALO agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call BUFFALO agent or qualified technician
Model
Voltage
Power
Current
Capacity
Weight
Dimensions
h x w x d mm
CD405
230V 50Hz
1500W
7A
1.2 litre
0.7kg
205 x 148 x 205