GENTRi10 10,000 Surge Watt / 8,500 Running Watt Portable Tri Fuel LPG & Gasoline & Natural Gas Electric Start Generator Manual
18
STOPPING THE GENERATOR
To stop this generator:
1. Turn off all connected electrical devices and then unplug them.
2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.
3. Turn off the engine switch.
4. If using LP Propane or Natural Gas, turn the tank fuel valve to the “off” position.
Allow this generator to cool down before touching areas that become hot during operation.
MAINTENANCE/CARE
Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator
as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 10.
STOP!
If you have questions about maintenance procedures described in this manual,
call 1-866-460-9436 , Monday - Friday, 8 AM - 4 PM Central Time.
Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance
procedures. Keep heat, sparks and flame away.
Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause
death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.
Recommended Maintenance Schedule
Each Use
Every Month or
Each 20 Hrs
Every 3 Months or
Each 50 Hrs
Every 6 Months or
Each 100 Hrs
Every Year or
Each 300 Hrs
Engine Oil
Check Level
X
Replace
X (First Use)
X
Air Filter
Check
X
Clean
X
Fuel Filler Cap
Clean
X
Spark Plug
Check/Clean
X
Clean
X
Figure 10 - Recommended maintenance schedule
Cleaning the Generator
Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush,
vacuum and/or pressurized air.
Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion.
Never use gasoline to clean parts of this generator.