INTRODUCTION
FCC RADIO FREQUENCY INTERFERENCE STATEMENT
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by LEITCH could void the user’s authority to operate this
equipment. Shielded cables must be used with this equipment to maintain compliance with FCC regulations.
WARRANTY STATEMENT
LEITCH warrants that the equipment it manufactures is free from defects in materials and workmanship.
Equipment that has been operated within its ratings and has not been subjected to mechanical or other abuse or
modification and has failed because of such defects, will, at the option of LEITCH, be repaired or replaced if it is
returned, freight pre-paid, to LEITCH within two years from the date of shipment. Equipment that fails under
conditions other than described herein will be repaired at the price of parts and labor in effect at the time of repair.
This warranty is in lieu of all other warranties, express or implied, including, but not limited to, any implied warranty
of merchantability or fitness for a particular purpose. LEITCH is not liable for any consequential damages.
OVERVIEW
The SUPERSLIDE Instant Replay Control System is designed specifically to control Leitch/ASC VR300
Video/Audio Server Systems that use shared media such as a Fibre Channel disk array. Up to ten channels can
be controlled, usually configured as five full-time record channels and five matching playback channels. The
“Platform 1” VR300 has one channel capable of high quality slow motion output complete with vertical “bobble”
cancellation, and one channel suitable for record purposes. The SUPERSLIDE provides a simple means for
putting record channels into a loop record mode, usually using time of day timecode. Playback is controlled on
matching playback channels in a way that allows frame accurate simultaneous playback of multiple channels and
GPI control that inherently lets the Technical Director choose which channel(s) to roll, and when to roll them.
PHYSICAL
The SUPERSLIDE control panel requires only ten inches width by eight inches depth of console space, and has a
sloped control surface for easy user access. Two backlit alphanumeric displays separate clip and menu operations
from status and timecode display. Playback control is always instant regardless of where the operator may be in
the menu system. The playback control keys are placed within easy reach of the high quality optical encoded
knob. The Slide, implemented using a motorized linear fader, is used for speed control. A numeric keypad allows
quick entry of timecode and random access clip selection. A MAKE CHILD key creates one or more child clips
(subclips) from record or playback clips.
The RM-4000-L Remote Processor rear panel includes ten separate DB9F connectors for connection to ten
channels of VR300, a power supply connection, a DB15F GPI connector, and two RJ45 8-pin modular telephone
connectors for connection to the control panel.
INSTALLATION
Install the RM-4000-L into an equipment rack and connect the included power supply. Connect the control panel
and Slide to the RM-4000-L via the included 15 foot RJ45 cables. Longer cables may be used, but the maximum
length is restricted to about 50 feet (15 meters) by voltage drop from the power supply (9.5VDC minimum at the