background image

Install New Fuel Tank Vent Valve (All Models)

The Fuel Tank Vent Valve was redesigned for 1999 and
later models. Certain models of 1995 through 1998 Buell
Motorcycles must have the new Fuel Tank Vent Valve
Assembly installed (Safety Recall Code 0815). If your
model has not had the assembly installed, you must
install the new Fuel Tank Vent Valve (Part Number
93923Y) at this time. The Vent Valve Tool Kit (Part
Number 91432-96Y) will also be necessary for installing
the replacement Vent Valve Assembly. See your Buell
Dealer for more details.

NOTE

All Models: When performing the following Steps, you will
need the Fuel Tank Vent Valve Installation Kit (Part Number
91432-96Y). This kit consists of: 

* Fuel Tank Vent Valve Installation Aid
* Fuel Tank Vent Valve Fitting Socket

13. Wipe inside and outside of vent valve mounting hole to

make sure there is not gasoline or excess Hylomar
sealant present.

14. See Figure 3. Using the Fuel Vent Valve Installation aid,

lower the fuel tank vent valve into the fuel tank through
the filler neck.

15. Position the fuel tank vent valve so the threaded portion

at the top protrudes from the fuel vent opening on the
fuel cap flange. Verify hole on top of vent valve is not
blocked by Hylomar sealant and that vent protrudes
completely from hole.

NOTE

The fuel vent fitting is installed DRY. Do NOT use teflon tape
or LOCTITE products when installing vent fitting.

16. Refer to Figure 2. Install new O-ring in groove on bottom

of new vent valve fitting.

17. While holding vent valve with fuel vent valve installation

aid, install fitting and O-ring to threaded portion of vent
valve. Do not tighten. Remove fuel vent valve installation
aid.

NOTE

It may take a few tries and slight rotation of the vent valve to
get the alignment mentioned in the following Step.

18. See Figure 4. Obtain new vent fitting from kit. Align fitting

so right front point of hex is oriented to 12:00 position
when fitting is tightened finger tight. Make sure O-Ring
remains in groove of fitting while tightening.

Do not overtighten vent fitting or attempt to tighten with
standard “click-type” torque wrench. Overtightening
vent fitting will cause it to snap off and fall into fuel tank.

19. Using a Dial-Type torque wrench, tighten vent fitting to

40-60 in-lbs (4.5-6.8 Nm).

NOTE

If fitting nozzle does not point to 12:00 position when
tightening within specified torque range, loosen fitting, rotate
vent valve and try again. Repeat as necessary to obtain
proper alignment of nozzle within specified torque range.

CAUTION

1

WARNING

3 of 4

-J02248

Figure 3. Installing Fuel Tank Vent Valve

i04326

Vent Valve

Installation Aid

Figure 2. Installing New Gas Cap Components 

New Fuel
Cap Boot

New Fuel Cap

Flange

O-Ring

New Vent

Valve Fitting

i04325

Figure 4. Fuel Tank Vent Alignment

Right Hex Point Should Point to

12:00 Position When Finger Tight

Then Tighten to 40-
60 in-lbs (4.5-7 Nm)

with Dial-Type

Torque Wrench.

Nozzle should

Point to 12:00.

Nozzle

i04327

Summary of Contents for 61861-01Y

Page 1: ...installed the resulting sparks may cause a battery explosion which could result in death or seri ous injury 1 Disconnect battery cables negative cable first An open flame or spark may cause a fuel tank explosion if all traces of fuel are not purged from the tank Use extreme caution when servicing fuel tanks Gasoline is extremely flammable and highly explosive Do not smoke or allow open flame or sp...

Page 2: ...tic parts and a small metal ball which if dropped into the fuel tank could cause plugging of fuel tank and fuel lines b Using the angled needle nose pliers pull the vent valve from the gasket Be careful not to tip or drop the vent valve or check balls c Discard the vent valve check balls and fitting 1999 and Later Models and 1995 1998 Models equipped with New Recall Code 0815 Vent Valve Assembly R...

Page 3: ...talling vent fitting 16 Refer to Figure 2 Install new O ring in groove on bottom of new vent valve fitting 17 While holding vent valve with fuel vent valve installation aid install fitting and O ring to threaded portion of vent valve Do not tighten Remove fuel vent valve installation aid NOTE It may take a few tries and slight rotation of the vent valve to get the alignment mentioned in the follow...

Page 4: ...rocedures Pressurize fuel tank Always connect the positive battery cable first If the positive cable should contact ground with the negative cable installed the resulting sparks may cause a battery explosion resulting in death or serious injury 26 Connect Battery Cables positive cable first Snorkel Inspection 1999 M2 Cyclone Models Only 1 See Figure 6 Remove the four screws nylon washers and air c...

Reviews: