2
Product Information
SM80/5, SM100/5 – 6 720 800 156 (2017/07)
8
2.7
Physical and connection dimensions
Fig. 5
Physical and connection dimensions
SM80/5
SM100/5
A
Diameter
inch (mm)
26-3/8 (670)
26-3/8 (670)
B
Minimum floor weight carrying capacity
lb (kg)
899 (408)
1135 (515)
C
Clearance off floor
inch (mm)
3/8 - 3/4 (10 - 20)
3/8 - 3/4 (10 - 20)
D
Overall height
inch (mm)
58-7/8 (1495)
72-1/4 (1835)
E
Height, cold water inlet
inch (mm)
3-1/8 (80)
3-1/8 (80)
F
Height, solar return
inch (mm)
12-1/2 (318)
12-1/2 (318)
G
Height, sensor well for temperature sensor (solar)
inch (mm)
24-21/64 (618)
31-7/32 (793)
H
Height, solar supply
inch (mm)
28-1/2 (722)
35-3/8 (898)
i
Height, tank return
inch (mm)
32 (813)
40-5/8 (1033)
J
Height, recirculation connection
inch (mm)
35-1/2 (903)
45 (1143)
K
Height, sensor well for temperature sensor
(heat source or aquastat)
inch (mm)
39-7/8 (1013)
50-5/16 (1278)
V
Boiler flow connection height
inch (mm)
44 (1118)
54-1/2 (1383)
M
Height, hot water outlet
inch (mm)
53-3/8 (1355)
66-3/4 (1695)
N
Minimum room height for anode replacement
inch (mm)
72-7/8 (1850)
82-3/4 (2100)
O
Empty weight
lb (kg)
260 (118)
298 (135)
P
Total weight when filled
lb (kg)
899 (408)
1135 (515)
Table 6
C
D
E
F
H
I
J
K
L
M
N
G
B
A
O
P
M1
M2
6 720
8
00 155-21.2ITL
B