10
We reserve the right to make any changes due to technical modifications!
Installation and Maintenance Instructions Logalux S 120 „US“• Issue 07/2001
Buderus Heiztechnik GmbH • http://www.heiztechnik.buderus.de
Assembly and Installation
4
4.3.2 Installation of Honeywell Aquastat
Remove cover from aquastat by removing hex head
screw on top.
Secure mounting bracket (Fig. 8,
Item. 3
) furnished
with tank to base of aquastat (Fig. 8,
Item. 2
) using
the 2 screws (Fig. 8,
Item. 1
). (One may need to
remove prior mounting bracket).
Insert aquastat capillary with tension spacer (Fig. 9,
Item. 4
and
5
) into tank dry well (Fig. 9,
Item. 3
).
Secure aquastat assembly (Fig. 9,
Item. 2
) with 2
screws (Fig. 9,
Item. 1
) to the tank jacket.
Put aquastat cover back in place.
Fig. 8
Attaching bracket to aquastat
Item. 1:
Screws C-ST 4,2 × 13 mm
Item. 2:
Aquastat
Item. 3:
Bracket
1
2
3
Fig. 9
Installation of Honeywell aquastat
Item. 1:
Sheet metal screws C-ST 4,2 × 13 mm
Item. 2:
Aquastat
Item. 3:
Tank dry well
Item. 4:
Aquastat capillary
Item. 5:
Tension spacer
1
2
3
4
5
NOTICE
Wire the aquastat into suitable control and
set desired DHW tank temperature at
aquastat.
DANGER!
DANGER
due to electricity.
Shut down main switch before working
on the boiler/tank system.