▶ Snap burner cable with strain relief into cable entry (
Fig. 57, [1]).
▶ Insert the burner cable with strain relief into the burner door
cladding.
▶ Route the burner cable up along the folded edge of the burner door
cladding and fasten with the cable clamp to ensure the burner cable
does not come into hot components of the boiler.
▶ Fit the burner door cladding on the burner door from the front and
screw on with four machine screws (
Fig. 57, [2 to 5]).
▶ Route the burner cable to the cable entry for the control panel.
Fig. 57 Installing the burner door cladding
▶ Attach the burner door panels to the burner door cladding
(
Fig. 58, [1 and 2]).
Fig. 58 Attaching the burner door panels
▶ Subject to the boiler location, affix the type plate to the top right or
left side panel where it can be clearly seen.
6 720 642 623-55.1o
4
5
3
1
2
6 720 642 623-56.1o
2
1
When the boiler is supplied ready-assembled, the type
plate can be found in the combustion chamber
accompanied by the assembly and maintenance
instructions; when the boiler supplied in separate
sections, it can be found in the transparent pocket on the
burner door.