![Buderus Logalux Installation And Maintenance Instructions Manual Download Page 6](http://html.mh-extra.com/html/buderus/logalux/logalux_installation-and-maintenance-instructions-manual_2826419006.webp)
2
Product Information
Logalux LT160/1 | LT200/1 | LT300/1 – 6 720 811 745 (2021/10)
6
2.3
Product Information
Fig. 2
Product Information
2.4
Data plate
The data plate is located at the top rear of the DHW tank.
2.5
Pressure drop curve of heating coil
Fig. 3
Pressure drop diagram
[1]
LT300/1
[2]
LT200/1
[3]
LT160/1
6 720 810 502-18.1T
2
1
1
11 10
9
8
7
6
5
4
4
6
2
5
7
3
3
Item
Description
1
Inspection port for service and cleaning
2
DHW outlet
3
DHW tank return
4
DHW tank supply
5
Recirculation connection (or aquastat installation)
6
Tank drain
7
Cold water inlet
8
Casing, painted sheet metal with rigid polyurethane foam
insulation
9
Heat exchanger for heating by boiler, smooth enameled tubing
10
Tank, enameled steel
11
Electrically insulated magnesium anode installed in inspection
port
Table 4 Product Information