Page 1: ... 1 5644 247 8 95 GB Operating instructions Control panel HS 2102 Buderus HEI Z T E CHNIK 1 Read first then operate Save these instructions ...

Page 2: ...er and safety information 4 Economic heating and energy saving measures 5 Flue gas test 6 Operating elements 7 8 Brief operating instructions 9 15 Operating instructions 16 24 BFC remote control 25 26 Malfunctions 27 29 Emergency operation 30 Index 31 ...

Page 3: ...trol speaks your language Each function is assigned to a button When a button is pressed down the values can be changed with the knob The new value is accepted when you release the button The control panel is fitted with the following functions 1 channel time switch with weekly program automatic summer winter changeover domestic water priority switch domestic water heating 30 minutes before heatin...

Page 4: ...ntries modify the control programs for the heating system and can lead to malfunctions Warning Hot water can scald Always turn the cold water tap on first and then mix in the amount of hot water required Frost protection The frost protection is always active when the control panel is switched on Pay attention to the risk of frost damage when you switch the heating system off with the On Off switch...

Page 5: ...ing system Have the heating system serviced regularly Ventilate rooms shortly but thoroughly in winter Do not let rooms cool down Check the settings of the thermostats in individual zones on a regular basis Do not set the room temperature or domestic water temperature higher than necessary Check to ensure that the programmed schedule normal setback agrees with your normal daily routine both for sp...

Page 6: ...re are displayed The control panel automatically switches back to the previous operating mode after 30 minutes Press the liJ button again and hold it down for 1 second to interrupt or prematurely end the flue gas test Caution Domestic water must not be drawn off unmixed during the test when the domestic water circuit of the heating system has no thermostat controlled mixing valve Risk of scalding ...

Page 7: ... HS 2102 Operating elements Safety temperature limit stat AllrGt tFH III I II 2 I i l l J Boiler water thermostat Switch for Domestic water emergency operation Switch for Heating emergency operation On Off switch 7 ...

Page 8: ... 1 1 S r rrr I 1 I I_ 1 1_ Buderus Ecomatic 2000 Knob I 0 0 0 0 w I d number of days am morning pm afternoon Time Automatic operation with time switch 0 Continuous day operation Continuous night operation 0 0 8 0 al Flue gas test Operating level 2 Cover plate open Select program Enter day of week Enter vacation g Add switching times 8 r Set time Display values ill Change temperatures or switching ...

Page 9: ...r for the control panel these instructions Startup Set boiler water thermostat to AUT Set domestic water heating to Set boiler circuit switch to Set On Off switch to I Shutdown Set On Off switch to In the case of danger switch off the emergency switch outside the heating room Your heating technician will demonstrate how to operate the heating system in detail Domestic water is heated with priority...

Page 10: ...ting 5 30 23 00 normal heating 6 30 23 30 normal heating 7 00 22 00 normal heating Operating mode Jnormal heating day A green control lamp above the button signals operation The day room temperature is held independent of the time of day in this mode The time switch function is not active Example You are having a party and the rooms should be heated longer Press the button Press after the party Op...

Page 11: ...he time is now stored Day and time blink after a power failure Switching between summer winter time Open the cover flap Press the button Press and hold down the Time button Turn the knob to the left or right for summer or winter time Set as for Setting time and date The heating then starts with factory program 1 when you have completed all of the operating steps This only applies to the initial st...

Page 12: ...s and hold down the PROG selection MY PROG appears in the display Turn the knob until the program you want appears for example 2 Early Release the Select PRoG button The heating now runs with program 2 1 channel time switch The control panel is fitted with a 1 channel time switch that controls the heating as well as the domestic water heating The domestic water heating always starts 30 minutes bef...

Page 13: ...12 00 23 00 Half day work mornings 6 6 30 23 30 7 7 00 22 00 5 AFTER 1 4 6 00 11 30 16 00 22 00 5 6 30 12 00 15 00 23 00 Half day work afternoons 6 6 30 23 30 7 7 00 22 00 6 MIDDAY 1 4 6 00 8 00 11 30 13 00 17 00 5 6 00 8 00 11 30 23 00 Midday at home 6 6 00 23 00 7 7 00 22 00 7 SINGLE 1 4 6 00 8 00 16 00 22 00 5 6 00 8 00 15 00 23 00 6 7 00 23 30 7 8 00 22 00 8 SENIOR 1 7 5 30 22 00 9 EMPTY The n...

Page 14: ...utton WWATER appears in the display Turn the knob until the required domestic water temperature appears for example 50 C Release the button The domestic water temperature is stored Switching off domestic water heating Press the button Press and hold down the button Turn the knob to the left until OFF appears in the display 14 lJlJRTER oc 50 0 cc ...

Page 15: ...he value is stored Setting continuous summer operation Press and hold down the button Turn the knob to the left until SUMMER appears in the display The display remains set to SUMMER Setting continuous winter operation Press and hold down the button Turn the knob to the right until WINTER appears in the display After the control panel has automatically changed to summer operation AUTOMATIC appears ...

Page 16: ...ob to display your current program for each day Turn the knob with the cover flap shut The display changes to MY PROG and the day and switching times of the program appear sequentially on the bottom line You can change this standard program and create a different program suiting your individual requirements You have approximately 10 seconds to complete each step otherwise the unit switches back to...

Page 17: ... 12 00 ON appear in the display Turn to day 1 Press and hold down the Time button Use the knob to set 8 00 Press and hold down the Temp button Turn the knob until OFF appears The new switching time is stored when you release the buttons The display automatically switches back to the previous mode of operation after approx 10 seconds 712 00 f l l PROG i 1 8 00 01 1 0 cL I 17 ...

Page 18: ...sired time appears Press and hold down the Temp ffi button Turn the knob to ON or OFF The new switching time is stored when you release the button It is better to enter both ON and OFF switching points Adding a switching time for the current time for example Mo 14 00 OFF Press and hold down the Add button ADD the current day and time rounded down to the next 10 minutes as well as ON and OFF appear...

Page 19: ...ed with the knob Press the button and hold it down until all the digits have disappeared from the display The switching time is now cancelled Attention The switchin 9 __time is not cancelled when you release the 5 button before all the digits have disappeared f l l PROG 771 00 01 1 88 88 19 ...

Page 20: ...ton Turn the knob until ADD appears in the display Press the Add button Press and hold down the Time button Turn the knob until 5 00 appears Press and hold down the Temp button Turn the knob until ON appears The switching point is stored when the Temp 6 button is released Press the Add button Press and hold down the Time button Turn the knob until 22 00 appears Press and hold down the Temp button ...

Page 21: ...emp ill button Turn the knob until ON appears The switching point is stored when the Temp button is released Press the Add button Press and hold down the Time button Turn the knob until 21 30 appears Press and hold down the Temp ill button Turn the knob until OFF appears The switching point is stored when the Temp button is released You can program all further switching points this way Y 30 01 1 2...

Page 22: ... value when the room temperature is too low Press the day button MANUAL the day time and day room tempe rature appear in the display Press and hold down the Temp button DAYTEMP appears in the display Turn the knob to the required day room tempe rature for example 24 0 C Release the button and the value is stored Press the E button Entering the night room temperature Press the night button MANUAL t...

Page 23: ...ple 15 Press and hold down the Temp button Turn the knob to the room temperature to be held during your vacation for example 10 C Release the buttons and your vacation period and room temperature are stored The domestic water is not heated during your vacation Cancelling the vacation program Press and hold down the Vacation Q button Turn the knob to the left until VACATION 00 appears in the displa...

Page 24: ...ld down the Display DJSP button Turn the knob and view the following current values sequentially in the display 24 boiler water temperature domestic water temperature outdoor temperature hours run of the burner room temperature when remote control connected flue gas temperature when flue gas sensor fitted BOILER oc o o ...

Page 25: ...dows The room temperature sensor in the remote control or external transmits variations in temperature to the electronic control panel where they are automatically equalised by raising or lowering the boiler water tempera ture Reduced heating operation Setting the night room temperature equivalent to reduced heating operation Set slide switch to the desired night room temperature e g 15 C Slide sw...

Page 26: ...23 00 normal heating Sa 6 30 23 30 normal heating Su 7 00 22 00 normal heating Operating mode 00 normal heating day A green control lamp in the button signals operation The day room temperature is held independent of the time of day in this mode The time switch function is not active Example You are having a party and the rooms should be heated longer Press the I button Press rrJ after the party O...

Page 27: ...malfunction repaired immediately by a qualified heating company Tell the heating company on the telephone which message has been displayed Set the switches as described under the Section Emergency operation Burner malfunction Display BURNER ERR The heating remains cold Clearance Press the burner reset button The malfunction message reappears when this attempt was unsuccessful When the burner does ...

Page 28: ... ERR The control can be defective when the domestic water remains cold Clearance Turn the switch for domestic water heating emergency operation on the control panel to Manual The heating system runs without the electronic program in emergency operation The boiler water temperature determines the domestic water temperature Set the boiler water thermostat to 60 C Warning The domestic water can reach...

Page 29: ...ntrol and can only be cleared by the Technical Service Clearance Call the nearest Technical Service Temperature sensor defective Display BOILER S ERR OUTDOOR S ERR cc WWATER S ERR The control is based on maximum values for the sensors The heating heats at different times and temperatures to those set Domestic water is not heated for safety reasons Clearance Call a qualified heating company and tel...

Page 30: ...hermostat Switch for domestic water heating emergency operation Switch for boiler circuit emergency operation Set the On Off switch to I Malfunction Living area heating not running Domestic water not being heated Both living area and domestic water heating not running J 1 1 l Settings for emergency operation Operating Boiler circuit Domestic Boiler water switch emergency water heating thermostat s...

Page 31: ... 25 Domestic water temperature 14 Room temperature too warm 22 25 E s Emergency operation 30 Safety information 4 Emergency switch 9 Service technician 6 Empty program 20 Setback heating operation 25 Energy saving measures 5 Standard programs 13 Summer I winter changeover 15 Summer I winter time 11 F Switch points add cancel 18 19 Factory programs 1 8 12 13 Switching off the heating 9 Flue gas tes...