Initial start-up
2
Installation and servicing instructions condensing gas boiler 800 - 24/29/43/60 and 800 - 24T25/29T25 H/V • edition 02/2006
25
Subject to modifications resulting from technical improvements !
Buderus • http://buderus-domestic.co.uk
2.2.2
Settings
Setting the flow temperature
z
Set the controller (fig. 31, item 2) to the desired maximum
flow temperature in accordance with the system design
and table 6.
Factory setting = 80
°
C (controller poition 10).
fig. 31 Controls
Key to fig. 31
Item 1:
Main switch
Item 2:
Flow temperature controller
Item 3:
Domestic hot water temperature controller
Item 4:
Jumper 11/50 kW to limit capacity
Item 5:
Pump over-run time switch
Item 6:
Heating capacity controller
Item 7:
Cover for second control level
1
2
10
0
1
11
kW
10
10
1
1
1 2 3
7
4 5
6
Controller position
Flow temperature in °C
1
40
2
44
3
48
4
53
5
58
6
62
7
67
8
71
9
76
10
80
Table 6
Flow temperature