6.4

Frost hazards for the heating system

Where there is a risk of frost damage to the heating 
system:

z

Open the control panel cover.

z

Open the cover of control level 2 (fig. 5, item 1).

z

Turn the "pump" switch 

(

 into position "

2

(24-hour pump over-run time) (fig. 5, item 5).

z

Close the covers of control level 2 and of the control 
panel.

6.5

Operational and fault messages 
(table 3)

Operating conditions or possible faults are shown on the 
display (fig. 5, item 4). The message is displayed in form 
of two characters. The second character is displayed 
after pressing the service button (fig. 5, item 3).

All messages not contained in table 3 should be recor-
ded as these refer to malfunctions and faults that should 
be rectified or eliminated by a specialist technician.

Fig. 5

Operational and fault messages

Tab. 3

Operational and fault messages

* flashing after three start-up trials

7

Shutting down the boiler

z

Open the control panel cover.

z

Turn the mains switch (fig. 6, item 1) into position "

0

".

z

Close the gas service valve by turning it to the right 
(fig. 6, item 2).

z

Close the control panel cover.

z

Long shutdown periods also require the water feed 
pipe to be closed.

Frost hazard for the heating system

z

Turn the mains switch into position "

I

" and leave the 

gas service valve open.

z

Use the control unit or remote control unit to set the 
room temperature to minimum or to frost-proof.

I

NOTE!

If you intend to fully shut down the system under 
frost hazard conditions, the water has to be 
drained from the entire system.

The use of antifreezing compounds is 
prohibited.

To drain the system take the following steps:

z

Close the CH flow and the CH return service valve.

1

2

10

1

0

1

11

KW

10

1

10

1

0

I

1

2

10

1

0

1

11

KW

10

10

1

2 3 4

5

1

Display

Display after pressing 
the service button

Meaning

Rectification

0

A, H, L, P, U, Y

Boiler is ready for operation

6

*

A

Burner not ignited

Press reset button (fig. 5, item 2) and 
keep it pressed for about 5 seconds. 
If the burner is not ignited after 
several unlocking operations, consult 
a specialist company.

-.

H

Normal heating operation

=.

H

Normal

 

hot water operation

Summary of Contents for 800 - 24

Page 1: ...7212 3700 02 2006 GB EN For the user Please read thoroughly before operating the unit Users manual Gas wall hung Boiler condensing Buderus 800 24 29 43 60 and Buderus 800 24T25 29T25 H V...

Page 2: ...tallation and Use Regulations The Building Regulations current I E E Wiring Regulations and the relevant British Standard Codes of Practice The device may only be used in combination with the units ac...

Page 3: ...ammable materials or liquids near the heating boiler I NOTE To prevent the boiler from being damaged care must be taken not to contaminate the combustion air with halogenated hydrocarbons e g containe...

Page 4: ...ns switch fig 1 item 5 into position I The boiler runs through the start up program and the burner is ignited after approx 30 seconds z Close the control panel cover z Use the control unit or remote c...

Page 5: ...Move the mechanical switch on the three way valve to centre position fig 2 applicable for 24T25 and 29T25 only and systems with an external storage type water heater z Connect temporary hose of the fi...

Page 6: ...three start up trials 7 Shutting down the boiler z Open the control panel cover z Turn the mains switch fig 6 item 1 into position 0 z Close the gas service valve by turning it to the right fig 6 ite...

Page 7: ...5 H V Edition 02 2006 7 Subject to modifications resulting from technical improvements Buderus Ltd http www buderus domestic co uk z Place hose on the draining tule z Turn to drain the system Fig 6 Ma...