Servicing
5
36
Installation and maintenance instructions for wall-mounted condensing gas boiler 600 - 11S/19S/24S/24C • 02/2006
Buderus • http://www.buderus-domestic.co.uk
Subject to modifications resulting from technical improvements!
5
Servicing
5.1
Operating codes
NOTE
If the code displayed on the burner-control unit
is not listed under the operating codes or fault
warnings, the burner-control unit itself is
malfunctioning.
Display
Display after
pressing the
service button
Meaning
0
Buderus 600 - 11S/19S/24S/24C is ready for operation
A
Burner interval circuit, 10 min. from burner start-up
C
Waiting for activation of the three-way valve (if fitted) or pump
H
Stand-by activated, Buderus 600 - 11S/19S/24S/24C ready to provide heat or hot water
L
Initial safety period: self-testing of burner-control unit during burner start-up
U
Post- or pre-purging period of fan unit
Y
Flow temperature at adjustment setting
-.
Buderus 600 - 11S/19S/24S/24C running in heating mode
A
“Chimney-sweep” mode, flow-temperature controller bypassed,
Buderus 600 - 11S/19S/24S/24C heating to previously-entered flow temperature.
H
Normal heating mode
Y
Service mode
=.
Buderus 600 - 11S/19S/24S/24C running in hot-water mode
H
Normal hot water mode
r
Reset