Taking the system out of service

z

Turn off the boiler by pressing the mains switch to "

0

" (fig. 4, 

item 1).

z

Close the gas service valve by turning it clockwise

 

(fig. 7, item 1).

Frost protection

The boiler has an automatic frost protection. When the CH flow 
temperature drops below 7 °C then the boiler will start up.

11.1

Draining the system in case of frost

It is not recommended, but if the boiler needs to be shut down 
for a longer period of time, then it is necessary to drain the sys-
tem. Especially when there is a chance for frost conditions. 

z

Turn off the boiler by pressing the mains switch to "

0

" (fig. 4, 

item 1).

z

Close the gas shut off valve (fig. 7, item 1).

z

Drain the system at its lowest point using the stop valves or 
radiator (see fig. 8). The automatic air vent at the system’s 
highest point must be open.

fig. 7

Gas service valve

1

2

1

: Gas valve closed

2

: Gas valve open

fig. 8

Draining the system

Summary of Contents for 500-24S

Page 1: ...7215 3200 07 2007 GB IE en For the user Please read thoroughly before operating the unit Users manual Gas wall hung Boiler condensing Buderus 500 24S...

Page 2: ...ilding Regulations current I E E Wiring Regulations and the relevant British Standard Codes of Practise The device may only be used in combination with the units accessories and spare parts listed in...

Page 3: ...eration 7 10 2 Operational and fault codes 9 11 Taking the system out of service 10 11 1 Draining the system in case of frost 10 Preface Dear Customer Your Buderus 500 Series wall mounted condensing g...

Page 4: ...urn Central Heating return IF YOU SMELL GAS DO NOT SMOKE OR STRIKE MATCHES DO NOT TURN ELECTRICAL SWITCHES ON OR OFF PUT OUT NAKED FLAMES OPEN DOORS AND WINDOWS KEEP PEOPLE AWAY FROM AFFECTED AREA TUR...

Page 5: ...manent clearances The boiler must be located in an area with the following perma nent clearances 5 mm 5 mm 8 mm 21 mm 21 mm NOTE The permanent clearances do not change if a wall spacing frame is used...

Page 6: ...d fault codes are displayed on the DBA see fig 2 5 Menu button E see fig 1 The menu button E allows you to scroll through the menu items Press the E button once to display the current DHW temper ature...

Page 7: ...3 item 1 and 2 z Connect filling loop fig 5 z Open both stop valves fig 5 z Fill the system to a pressure of approx 1 5 bar fig 3 item 3 z Close both stop valves z Vent the air from all radiators star...

Page 8: ...n The boiler will then only operate for DHW in combination with an external hot water cylinder z Press the E button see fig 6 item 2 twice The current setting blinks z Use the C and D keys to adjust t...

Page 9: ...able 1 should be noted down separately These are malfunctions that require the presence of a CORGI installer Display after pressing service button Meaning Rectification 0A 0C 0E 0H 0L 0U 0Y Boiler is...

Page 10: ...below 7 C then the boiler will start up 11 1 Draining the system in case of frost It is not recommended but if the boiler needs to be shut down for a longer period of time then it is necessary to drai...

Page 11: ...Note Users manual for Buderus 500 24S 07 2007 11 Subject to modifications resulting from technical improvements Buderus http www buderus co uk...

Page 12: ...www buderus co uk Buderus is a trading name of BBT Thermotechnology UK Ltd Customer Services Technical Product Support Sales Returns Spares Tel 0870 421 5933 Tel 0870 421 5944 Tel 01905 752 640 Tel 0...

Reviews: