Servicing manual Gas condensing boiler Buderus 500-24/S, 500-24/C and 500-28/C • Issued 02/2006
box 130 Check the glow ignitor – activation
H
DANGER OF FATAL ACCIDENT
due to electric shock
z
Take the boiler out of operation, see box 43, 44 or 47.
box 131
z
Pull out the plug of the glow ignitor (item 1).
box 132
z
Set the multimeter to “measure AC voltage”.
Minimum measuring range: 230V AC.
z
Put the boiler into partial-load or full-load operation,
z
Check to see whether, with the operating code
C [0c]
110 - 230 V AC is measured at the plug.
box 133
z
Take the boiler out of operation, see box 43.
z
Connect the plug of the glow ignitor.
z
Put the boiler into operation, see
1
box 134 Check the glow ignitor – resistance
H
DANGER OF FATAL ACCIDENT
due to electric shock
z
Take the boiler out of operation, see box 43, 44 or 47.
z
Remove the plug of the glow ignitor, see box 131.
box 135
z
Set multimeter to “measure resistance”.
z
Check to see if the electrical resistance of the glow ignitor
lies between 50 and 300
Ω
.
box 136
z
Connect the plug of the glow ignitor.
z
Fit the casing and place the boiler into operation,
box 137 Check the glow ignitor – power supply cable
H
DANGER OF FATAL ACCIDENT
due to electric shock
A
CAUTION!
To prevent damage, do not insert the measuring
electrodes of the multimeter too far into the holes of the
plug-and-socket connection.
z
Take the boiler out of serve and tip the DBA control panel
forwards, see box 43, 44, 47 or 63.
z
Loosen the six screws and remove the rear section,
z
Remove the plug of the glow ignitor, see box 131.