Troubleshooting
3
Subject to modifications resulting from technical improvements!
Buderus Ltd. • http://www.buderus-domestic.co.uk
24
Servicing manual for wall-mounted condensing gas boiler 600 Series 11S/19S/24S/24C • Issued 02/2006
Fig. 21
Fault warning message 6A: F1 fuse defective, or no ionisation message after ignition
Flashing
6
F1 fuse defective, or no ionisation
message after ignition
A
Yes
24
Fit the casing (page 48)
"reset"
600 Series 11S / 19S / 24S / 24C
OK
Is the gas-supply shutoff
valve open?
Gas-air ratio OK?
Remove the casing (page 48)
Gas connection pressure
OK?
Open gas-supply shutoff valve
Contact local gas-supply
utility
No
No
No
No
Yes
Yes
Yes
"reset"
Measure connection pressure (18 - 25 mbar),
as indicated in installation and servicing
instructions
Carry out the following tasks as shown in the
Installation and Servicing Instructions: Check
exhaust-gas system (operation independent of
room-air), Check gas-air ratio of supply
Adjust gas/air ratio as indicated in the
installation and servicing instructions
22
No
23
No
21
Yes
Yes
Did the incandes-
cent firing electrode glow
during ignition?
Did the gas valve
open during ignition? (Noise
from switch)
Is the fan running?