IMPORTANT INFORMATION-Electrical
Figure. 1
Figure. 2
SCM4500
This tool is intended to be used only with a Ground Fault Circuit Interrupter (GFCI)
type receptacle. Test GFCI before each use of the tool.
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the
pathof least resistance for electric current and reduces the risk of electric shock.
This tool is equipped with an electric cord that has an equipment grounding
conductor and a grounding plug. The plug MUST be plugged into a matching
electrical receptacle that is properly installed and grounded in accordance with ALL
local codes and ordinances.
3-prong
electrical
receptacle
grounding
conductor
grounding
adapter lug
3-wire electrical cord
3-prong
electrical
receptacle
grounding conductor
3-wire electrical cord
MINIMUM RECOMMENDED GAUGE FOR EXTENSION CORDS (AWG)
120 VOLT OPERATION ONLY
25’ LONG
50’ LONG
100’ LONG
150’ LONG
0 to 6 Amps
18 AWG
16 AWG
16 AWG
14 AWG
6 to 10 Amps
18 AWG
16 AWG
14 AWG
12 AWG
10 to 12 Amps
16 AWG
16 AWG
14 AWG
12 AWG