Page 10
DISCRIPTION
DATE
REV.
BY
INSTALLATION INSTRUCTIONS FOR MODEL ZCBB OPTIONAL
WOODEN FLUSH MOUNT MANTEL FRONT (FF) (KIT#PAKDMZCBBFF)
“NOTE: Follow framing instructions on pages 6 & 7. With the exception of placement of
ZCBB in framed opening . The ZCBB must be placed with the front surface of appliance 1-
9/16” out from finished wall. This well allow FF to set flush with front of ZCBB”.
CLEARANCES:
1.
Sidewall Clearances:
Clearances from side of firebox opening to any adjacent combustible
wall should not be less than 7". (See page 8, figure 4)
2.
Ceiling Clearances:
Ceiling height should not be less than 42" from top of firebox opening.
INSTALLATION INSTRUCTIONS:
1. After removing the FF kit from its packaging follow any pre-installation instructions provided
with kit.
2. Place FF over front of ZCBB, centering opening in FF left to right with ZCBB front.
3. Next you must secure FF to finished wall surface. You may use “L” brackets, screws or finishing
nails (not provided with FF).
NOTE:
If an unfinished FF kit is used, do not operate appliance while finishing wood or before fin-
ish has dried properly.
ZCBB
TOP VIEW
FINISHED WALL FACE
6”
60”
49-1/2”
53”
ZCBB
ZCBB & FF FRONTS
ARE FLUSH.
1-9/16”
FRONT VIEW
SIDE VIEW