Page 23
THERMOSTAT CONTROL OPERATION
The thermostat control used on this heater differs from standard thermostats. Standard
thermostats simply turn burner on and off. The thermostat used on this heater senses room
temperature and adjusts amount of gas flow to burner. This will increase or decrease
flame height. At times, room may exceed set temperature, which will cause burner to shut
off. When room temperature drops below thermostat setting, burner will cycle itself on
again. The flame control knob can be set to any level between 2 and 7.
NOTE:
The thermostat sensing bulb measures temperature of air near heater cabinet.
This may not always agree with room temperature ( depending on housing construction,
installation location , room size, open air temperature, etc.). Frequent use of your heater
will allow you to determine your personal comfort levels.
MANUAL LIGHTING PROCEDURE
1. If the pilot cannot be ignited with igniter on the control valve, it can be manually lit with
use of a paper match and a lighter rod.
2. Place the match in holder and light. With other hand, depress control knob
counterclockwise to PILOT.
3. Use rod to light match and ignite pilot. The pilot is located behind burner tub and in
front of rear log. Fully
open
manual shut-off valve.
4. Continue to hold control knob for an additional (1) one minute to ensure pilot
is completely on.
•
If knob does not pop up when released, stop and immediately call your service techni-
cian or gas supplier.
•
“If the pilot will not stay lit after several tries, turn gas control knob to
“OFF”
and call
your service technician or gas supplier.”
5. Turn control knob counterclockwise to
“ON”
position.
“Set thermostat (flame control) to desired setting. Turn clockwise for
“LOW”
and counterclockwise for
“HIGH”.
6. Close the access panel door.
7. “Turn on all electric power to appliance.”