BuckMaster FP-BR-10-ZC Manual Download Page 1

                               MODEL FP-BR-10-ZC 
                                        VENT-FREE 

WARNING: 

If  information in this manual is not followed exactly, a fire or ex-

plosion may result causing property damage, personal injury or loss of life.

 

 

− 

Do not store or use gasoline or other flammable vapors and liquids in  vicinity of this or 
any other appliance. 

   

 

      WHAT TO DO IF YOU SMELL GAS 

 

• 

 Do not try to light any appliance. 

• 

Do not touch any electrical switch; do not use any phone in your building. 

• 

Immediately call your gas supplier from a neighbor’s phone. Follow  gas supplier’s in-
structions. 

• 

If you cannot reach your gas supplier, call  fire department. 

 

− 

Installation and service must be performed by a qualified installer, service agency or the 
gas supplier. 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to 
section “ Producing Adequate Air For Combustion And Ventilation” page 14. 

This appliance may be installed in an aftermarket, permanently located, manufactured 
(mobile) home, where not prohibited by local codes. 

 

This appliance is only for use with type of gas indicated on  rating plate. This appliance is 
not convertible for use with other gases. 

MANUFACTURED BY NEW BUCK CORPORATION  

 

200 ETHAN ALLEN DRIVE,  

SPRUCE PINE, N.C.  28777                                                                          

www.buckstove.com

 

Revised  March 2012

 

 

NOTE: 

An unvented room heater having an input rating of more than 6,000 Btu per hour 

shall not be 

installed in a bathroom

INSTALLER: 

Leave this manual with  appliance. 

CONSUMER: 

Retain this manual for future reference.

 

WARNING: 

This appliance is equipped for (natural or propane) gas. Field conversion is not  

permitted. 

Summary of Contents for FP-BR-10-ZC

Page 1: ...heater It uses air oxygen from the room in which it is in stalled Provisions for adequate combustion and ventilation air must be provided Refer to section Producing Adequate Air For Combustion And Ve...

Page 2: ......

Page 3: ...ion 11 Mobile Home Installation 13 Gas Connection 13 Producing Adequate Air for Combustion and Ventilation 14 Air For Combustion And Ventilation Air Iinside Building 16 Air For Combustion And Ventilat...

Page 4: ......

Page 5: ...directly in front of heater pulling from either direction may create sooting Sooting will discolor walls 1 The installation must conform with local codes or in absence of local codes with National Fue...

Page 6: ...must be closed 12 Keep appliance area clean and free from combustible materials gasoline and other flammable flammable vapors and liquids 13 If burner shuts off do not relight until you provide fresh...

Page 7: ...y away to avoid burns or clothing ignition 27 Young children should be carefully supervised when they are in same room with appliance 28 An unvented room heater having an input rating of more than 6 0...

Page 8: ...and hot air grills may cause the flames to soot If a disturbance is found that affects the flames it must be eliminated by turning off ceiling fan closing the door or closing or moving th hot air reg...

Page 9: ...hould be performed by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exces...

Page 10: ...cureFirebox Secure fireplace to framing The nailing flanges on firebox will make securing firebox to frame quick and easy Use appropriate sizenailsor screwsto securefirebox FIREPLACECLEARANCES The fir...

Page 11: ...ce opening Check to see whether man made brick and stone are made of non combustible materials before using them on face of fireplace Some of these products contain combustible materials Combustible w...

Page 12: ...r Support must be Flush with top of Unit if mantel is 10 wide or less 12 2 1 2 3 4 3 3 1 2 Bottom of 3 4 Base or Support must be at least 2 1 2 from top of Unit if mantel is 10 wide or more 3 4 3 1 2...

Page 13: ...osed position before leaving heater unattended 3 Follow instructions for assembly of Optional Wooden Mantel See instructions supplied with mantel 4 After mantel has been assembled slide heater from re...

Page 14: ...Page 12 FIGURE 6 MANTEL BASE TOP MANTEL REAR OF HEATER 1 2 WOOD SCREWS 9...

Page 15: ...ment trap piping check local codes tee joint manual shutoff valve pipe wrench test gauge connection sealant resistant to LP gas WARNING ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS INSTA...

Page 16: ...HEATER MAY BE OPERATED DOES NOT MEET REQUIRED VOLUME FOR INDOOR COMBUSTION AIR COMBUSTION AND VENTILATION AIR SHALL BE PROVIDED BY ONE OF METHODS DE SCRIBED IN NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA...

Page 17: ...me of space 50 cu Ft 51 2 or 51200 maximum BTU Hr space can support 3 Add BTU Hr of all fuel burning appliances in space Vent free heater _______________BTU Hr Gas water heater _______________BTU Hr G...

Page 18: ...re inch per 1000 BTU s per hour of total input ratings of all gas utilization equipment in confined space but not less than 100 square inches Figure 7 Ventilation Air From Inside Building A Rework wor...

Page 19: ...ustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet air into attic if attic has a thermostat controlled power vent Heated air entering a...

Page 20: ...psi 3 5 kPa MODEL FP BR10 ZC FP BR10 ZC Gas Natural Propane Maximum Heat Input 10000 10000 Gas Inlet Pressure Maximum 10 5 ins W C 13 ins W C Minimum 5 ins W C 11 ins W C Manifold Pressure 3 5 ins W C...

Page 21: ...minated after first few hours of operation Do not use blower at this time Front View of Logs WARNING FAILURE TO POSITION PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICAL...

Page 22: ...gas supplier from a neighbor s phone Follow gas supplier s instructions If you cannot reach your gas supplier call your local fire department C Use only your hand to push in or turn the gas control kn...

Page 23: ...nd in front of rear log Fully open manual shut off valve 9 Turn control knob counterclockwise to PILOT position Press in control knob for 15 fifteen seconds see figure 3 10 With control knob pressed i...

Page 24: ...er of base for access to control knobs 2 Turn control knob clockwise to PILOT position 2 Close access panel door CAUTION Hot while in operation Do Not Touch Keep children clothing furniture gasoline a...

Page 25: ...to determine your personal comfort levels MANUAL LIGHTING PROCEDURE 1 If the pilot cannot be ignited with igniter on the control valve it can be manually lit with use of a paper match and a lighter r...

Page 26: ...resent when gas logs are in operation FLAME Propane LP should produce a flame that is 3 4 above rear log This flame should be yellow Natural gas should produce a flame that is 3 4 above rear log This...

Page 27: ...e as supplied with appliance must be replaced it must be replaced with a wire of at least a 105o C temperature rating NOTE Installation and repair should be done by a qualified service person This hea...

Page 28: ...DING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE NOTE PESBRO84 Blower Motor Rating 120 volts 60HZ 0 54 Amps 1 P H NOTE...

Page 29: ...LOGS OR OTHER PARTS OF THE HEATER BE SURE TO READ ABOVE SECTIONS ON IMPORTANT SAFEGUARDS The appliance must be turned OFF before cleaning inside firebox burn area make sure pilot is OFF completely and...

Page 30: ...zo igniter nut is loose 6 Broken igniter cable 7 Bad piezo igniter 1 Gas supply turned off or manual shutoff valve is closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in...

Page 31: ...artially clogged ODS Pilot 7 Control valve damaged 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged 5 Contact local propane gas co...

Page 32: ...old if equipped with this type of valve 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice 1 Clean burner See Clean ing and Maintenance or replace burner...

Page 33: ...room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and control all leaks See Checking Gas Connections 1 Open window door for ventilation 2 Contact local propa...

Page 34: ...ng any service operation Check for gas leaks after servicing REPAIR PARTS A parts list with exploded view follows Always include correct name part number and model number of heater when ordering servi...

Page 35: ...00 433 Thermo couple Copreci 1 7 PE 21500053 Copreci ODS Nat Pilot 1 7A PE 2150054 Copreci ODS LP Pilot 1 8 PE RV12LF30 Maxitrol Regulator Nat 1 8A PE RV12LF90 Maxitrol Regulator LP 1 9 RF 14ALMTUB 1...

Page 36: ...Page 34 BLOWN UP VIEW OF BURNER ASSEMBLY 16 Not shown on this page See page 25 figure 10 for wiring diagram...

Page 37: ...to parts that are not in original condition normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installa...

Page 38: ......

Page 39: ...rtified Installer s number if applicable for warranty coverage to begin NAME _____________________________________________________ ADDRESS __________________________________________________ CITY _____...