HOW TO LOCATE CHIMNEY EXIT AND INSTALL
Alcove Installation
Vertical Exit using (6" DVL Close Clearance pipe and any Listed 2100° UL 103 HT
chimney). Pipe shield must be used.
NOTE: For minimum clearances (See Page 21, Figure 20).
1. Suspend a plumb bob from the ceiling above unit so that weight is hanging in center of
flue exit. (A small weight on a string will serve as a plumb bob). Mark ceiling where
string is suspended to locate center of chimney.
2. After locating center of hole, install ceiling support box, chimney or chimney connector,
flashing and rain cap, per chimney manufacturer’s instructions and local building codes
for installation through combustible walls or ceilings.
3. Now connect stove and ceiling support box using DVL close clearance pipe. Connect
each section per manufacturer’s instructions.
4. Secure each section to each other using minimum (3) sheet metal screws or rivets.
DVL close clearance is to be connected with (3) sheet metal screws or rivets to
connector collar on heater.(See Page 21,Figure 21).