Installing the RFP Lifeline Flag:
1.
Open the hook & loop fastener strap located at the top of the flag (Fig. 13).
2.
Wrap the hook & loop fastener strap around the previously installed lifeline or re-direct line and secure the hook & loop
fastener together (Fig. 14). Note: Install the RFP lifeline flag in a location that is close to the anchor point and easily seen.
E.
Installing the Ladder:
1.
Following the ladder manufacturer’s instructions and
your
employer’s
work practices, install the ladder in the desired
location to reach the work area (Fig. 15).
Note: The ladder must be installed at the proper angle (approx. 75.5° or 4:1 ratio)
with a minimum of 3’ (but less than 6’) extended past the roof line.
Failure to properly install the ladder could result in
your serious injury or death.
F.
Attaching the P/N 5004BQ1 BuckArrester Mobile Fall Arrester (MFA) to the Lifeline:
1.
Ensure the UP arrow on the frame of the BuckArrester is facing the top of the ladder and up the lifeline (Fig. 16 - 17).
2.
Rotate the cam up into the open position (Fig. 18).
3.
Insert the tail of the lifeline through the top of the BuckArrester channel between the frame and the cam (Fig. 19 - 20).
4.
Slide the BuckArrester into the desired position on the lifeline (Fig. 21).
Integral
Attachment
Carabiner
(Z359.12)
BuckArrester
Mobile Fall Arrester
(MFA)
UP Arrow
(Must Point to Anchor)
Cam Lever
Locking Nut
Integral Lanyard
(with impact load indicator)
(MFA)
Frame
Fig. 16
Fig. 15
Work
Area
Lifeline
Pa
tent Pending
Hook & Loop
Fastener Strap
(open)
RFP Lifeline Flag
Fig. 13
Fig. 14